D-Dimer has a high sensitivity but a low specificity for the diagnosis of deep vein thrombosis (DVT) which limits its implementation as a general screening parameter. There is a demand for additional biomarkers to improve its diagnostic accuracy. Soluble platelet endothelial cell adhesion molecule 1 (sPECAM-1) is generated at the site of venous thrombosis, thus, represents a promising biomarker. Patients with clinically suspected DVT (N = 159) were prospectively recruited and underwent manual compression ultrasonography (CCUS) to confirm or exclude DVT. The diagnostic value of D-Dimer, sPECAM-1 and the combination of both was assessed. sPECAM-1 levels were significantly higher in patients with DVT (N = 44) compared to patients without DVT (N = 115) (85.9 [76.1/98.0] ng/mL versus 68.0 [50.1/86.0] ng/mL; p < 0.001) with a diagnostic sensitivity of 100% and a specificity of 28.7% at the cut point > 50.2 ng/mL. sPECAM-1 improved the diagnostic accuracy of D-Dimer: the combination of both biomarkers yielded a ROC-AUC of 0.925 compared to 0.905 for D-Dimer alone and 0.721 for sPECAM-1 alone with a reduction of false-positive D-Dimer cases 72-> 43 (Δ = − 31.9%). The discrimination mainly occurred in a subgroup of patients characterized by an inflammatory background (defined by c-reactive protein level > 1 mg/mL). sPECAM-1 represents a novel diagnostic biomarker for venous thrombosis. It does not qualify as a diagnostic biomarker alone but improves the diagnostic accuracy of D-Dimer in patients with suspected DVT.
Biomarkers, such as troponin-T and troponin-I, are regarded as the gold standard laboratory parameter for diagnosing many cardiological diseases. These parameters have been approved for clinical use. Many cardiological guidelines recommend the analysis of troponins in the majority of cardiological disease diagnoses and to also gain prognostic information. Nonetheless, many medical circumstances could cause false troponin elevations. In this article, we focus on troponin artifacts, particularly macro-immune complex formation, as important interference factors. Therefore, we performed a literature search from 2006 to 06/2021.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.