Time-of-flight secondary ion mass spectrometry (TOF-SIMS) has unique capabilities in the area of high-resolution mass spectrometric imaging of biological samples. The technique offers parallel detection of native and non-native molecules at physiological concentrations with potentially submicrometer spatial resolution. Recent advances in SIMS technology have been focused on generating new ion sources that can in turn be used to eject more intact molecular and biological characteristic species from a sample. The introduction of polyatomic ion beams, particularly C60, for TOF-SIMS analysis has created a whole new application of molecular depth profiling and 3D molecular imaging. However, such analyses, particularly at high lateral resolution, are severely hampered by the accompanying mass spectrometry associated with current TOF-SIMS instruments. Hence, we have developed an instrument that overcomes many of the drawbacks of current TOF-SIMS spectrometers by removing the need to pulse the primary ion beam. The instrument samples the secondary ions using a buncher that feeds into a specially designed time-of-flight analyzer. We have validated this new instrumental concept by analyzing a number of biological samples generating 2D and 3D images showing molecular localization on a subcellular scale, over a practical time frame, while maintaining high mass resolution. We also demonstrate large area mapping and the MS/MS capability of the instrument.
Transflection-mode FTIR spectroscopy has become a popular method of measuring spectra from biomedical and other samples due to the relative low cost of substrates compared to transmission windows, and a higher absorbance due to a double pass through the same sample approximately doubling the effective path length. In this publication we state an optical description of samples on multilayer low-e reflective substrates. Using this model we are able to explain in detail the so-called electric-field standing wave effect and rationalise the non-linear change in absorbance with sample thickness. The ramifications of this non-linear change, for imaging and classification systems, where a model is built from tissue sectioned at a particular thickness and compared with tissue of a different thickness are discussed. We show that spectra can be distorted such that classification fails leading to inaccurate tissue segmentation which may have subsequent implications for disease diagnostics applications.
Time-of-flight secondary ion mass spectrometry (ToFSIMS) is being applied increasingly to the study of biological systems where the chemical specificity of mass spectrometry and the high lateral resolution imaging capabilities can be exploited. Here we report a comparison of two cell sample preparation methods and demonstrate how they influence the outcome of the ToFSIMS analysis for three-dimensional (3D) imaging of biological cells using our novel buncher-ToF instrument (J105 3D Chemical Imager) equipped with a C(60) primary ion beam. Cells were analysed fixed and freeze-dried and non-fixed, frozen-hydrated. It is concluded that maintaining the cells in a non-fixed frozen-hydrated state during the analysis helps reduce chemical redistribution, producing cleaner spectra and improved chemical contrast in both 2D and 3D imaging. Insights into data interpretation are included and we present methods for 3D reconstruction of the data using multivariate analysis techniques.
Vibrational spectroscopies, based on infrared absorption and/or Raman scattering provide a detailed fingerprint of a material, based on the chemical content. Diagnostic and prognostic tools based on these technologies have the potential to revolutionise our clinical systems leading to improved patient outcome, more efficient public services and significant economic savings. However, despite these strong drivers, there are many fundamental scientific and technological challenges which have limited the implementation of this technology in the clinical arena, although recent years have seen significant progress in addressing these challenges. This review examines (i) the state of the art of clinical applications of infrared absorption and Raman spectroscopy, and (ii) the outstanding challenges, and progress towards translation, highlighting specific examples in the areas of in vivo, ex vivo and in vitro applications. In addition, the requirements of instrumentation suitable for use in the clinic, strategies for pre-processing and statistical analysis in clinical spectroscopy and data sharing protocols, will be discussed. Emerging consensus recommendations are presented, and the future perspectives of the field are assessed, particularly in the context of national and international collaborative research initiatives, such as the UK EPSRC Clinical Infrared and Raman Spectroscopy Network, the EU COST Action Raman4Clinics, and the International Society for Clinical Spectroscopy.
Transmission and transflection infrared microscopy of biological cells and tissue suffer from significant baseline distortions due to scattering effects, predominantly resonant Mie scattering (RMieS). This scattering can also distort peak shapes and apparent peak positions making interpretation difficult and often unreliable. A correction algorithm, the resonant Mie scattering extended multiplicative signal correction (RMieS-EMSC), has been developed that can be used to remove these distortions. The correction algorithm has two key user defined parameters that influence the accuracy of the correction. The first is the number of iterations used to obtain the best outcome. The second is the choice of the initial reference spectrum required for the fitting procedure. The choice of these parameters influences computational time. This is not a major concern when correcting individual spectra or small data sets of a few hundred spectra but becomes much more significant when correcting spectra from infrared images obtained using large focal plane array detectors which may contain tens of thousands of spectra. In this paper we show that, classification of images from tissue can be achieved easily with a few (<10) iterations but a reliable interpretation of the biochemical differences between classes could require more iterations. Regarding the choice of reference spectrum, it is apparent that the more similar it is to the pure absorption spectrum of the sample, the fewer iterations required to obtain an accurate corrected spectrum. Importantly however, we show that using three different non-ideal reference spectra, the same unique correction solution can be obtained.
In this study we obtained Fourier transform infrared (FTIR) spectra of fixed prostate cell lines of differing types as well as the primary epithelial cells from benign prostatic hyperplasia (BPH). Results showed that by using multivariate chemometric analysis it was possible to discriminate and classify these cell lines, which gave rise to sensitivity and specificity values of >94% and >98%, respectively. Following on from these results the possible influences of different factors on the discrimination and classification of the prostate cell lines were examined. Firstly, the effect of using different growth media during cell culturing was investigated, with results indicating that this did not influence chemometric discrimination. Secondly, differences in the nucleus-to-cytoplasm (N/C) ratio were examined, and it was concluded that this factor was not the main reason for the discrimination and classification of the prostate cancer (CaP) cell lines. In conclusion, given the fact that neither growth media nor N/C ratio could totally explain the classification it is likely that actual biochemical differences between the cell lines is the major contributing factor.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.