Acute primary open angle glaucoma is an optic neuropathy characterized by the elevation of intraocular pressure, which causes retinal ischemia and neuronal death. Rat ischemia/reperfusion enhances endocytosis of both horseradish peroxidase (HRP) or fluorescent dextran into ganglion cell layer (GCL) neurons 24 h after the insult. We investigated the activation of autophagy in GCL-neurons following ischemia/reperfusion, using acid phosphatase (AP) histochemistry and immunofluorescence against LC3 and LAMP1. Retinal I/R lead to the appearance of AP-positive granules and LAMP1-positive vesicles 12 and 24 h after the insult, and LC3 labelling at 24 h, and induced a consistent retinal neuron death. At 48 h the retina was negative for autophagic markers. In addition, Western Blot analysis revealed an increase of LC3 levels after damage: the increase in the conjugated, LC3-II isoform is suggestive of autophagic activity. Inhibition of autophagy by 3-methyladenine partially prevented death of neurons and reduces apoptotic markers, 24 h post-lesion. The number of neurons in the GCL decreased significantly following I/R (I/R 12.21±1.13 vs controls 19.23±1.12 cells/500 µm); this decrease was partially prevented by 3-methyladenine (17.08±1.42 cells/500 µm), which potently inhibits maturation of autophagosomes. Treatment also prevented the increase in glial fibrillary acid protein immunoreactivity elicited by I/R. Therefore, targeting autophagy could represent a novel and promising treatment for glaucoma and retinal ischemia.
ObjectiveThis pilot study evaluates the pressure lowering potential of subthreshold micropulse diode laser trabeculoplasty (MDLT) for a clinically meaningful duration in patients with medically uncontrolled open angle glaucoma (OAG).Designprospective interventional case series.ParticipantsThirty-two eyes of 20 consecutive patients with uncontrolled OAG (12 bilateral and 8 unilateral).MethodsConfluent subthreshold laser applications over the inferior 180° of the anterior TM using an 810 nm diode laser in a micropulse operating mode. The intraocular pressure (IOP) was measured at baseline and at 1 hour, 1 day, 1 week, 3, 6, 9, and 12 months post-treatment. Flare was measured with a Kowa FM 500 flare-meter at baseline and at 3 hours, 1 day, 1 week, and 12 months post-treatment. After treatment, the patients were maintained on their pre-treatment drug regimen.Main outcome measuresCriteria for treatment response were IOP reduction ≥3 mm Hg and IOP ≤21 mm Hg within the first week after MDLT. Eyes not complying to the above criteria during the follow-up were considered treatment failure. Mean IOP change and percentage of IOP reduction during the follow-up were calculated.ResultsOne eye was analyzed for bilateral patients. A total of 20 eyes were thus included. Four eyes (20%) did not respond to treatment during the first week. One additional eye failed at the 6 month visit. The treatment was successful in 15 eyes (75%) at 12 months. The IOP was significantly lower throughout follow-up (p < 0.01). At 12 months, the mean percentage of IOP reduction in the 15 respondent eyes was 22.1% and 12 eyes (60%) had IOP reduction higher than 20%. During the first two postoperative days, one eye with pigmentary glaucoma experienced a significant increase of flare associated with an IOP spike (34 mm Hg) that was controlled with systemic drugs; afterwards it qualified as a respondent and completed the study. No increase of flare was found in any other patient. No peripheral anterior synechiae formed.ConclusionsIn this case series, MDLT was effective in reducing IOP in 75% of medically insufficiently controlled OAG eyes without significant complications. This justifies randomized clinical studies to compare MDLT with current IOP lowering strategies.
Although most of the injuries seen in an Emergency Department in Italy were minor, they were associated with a significant morbidity. In Torino, most of the traumatic eye injuries occurred at work or at home. Preventive and informative measures are warranted to reduce the incidence and prevalence of eye casualties.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.