There are many reports comparing pulsatile and continuous-flow left ventricular assist devices (LVAD). But continuous-flow LVAD with the pulsatile driving technique had not been tried or discussed before our group's report. We have previously developed and introduced a power-control unit for a centrifugal LVAD (EVAHEART®; Sun Medical), which can change the speed of rotation so it is synchronized with the heart beat. By use of this unit we analyzed the end-diastolic volume (EDV) to determine whether it is possible to change the native heart load. We studied 5 goats with normal hearts and 5 goats with acute LV dysfunction because of micro-embolization of the coronary artery. We used 4 modes, "circuit-clamp", "continuous", "counter-pulse", and "co-pulse", with the bypass rate (BR) 100%. We raised the speed of rotation of the LVAD in the diastolic phase with the counter-pulse mode, and raised it in the systolic phase with the co-pulse mode. As a result, the EDV decreased in the counter-pulse mode and increased in the co-pulse mode, compared with the continuous mode (p < 0.05), in both the normal and acute-heart-failure models. This result means it may be possible to achieve favorable EDV and native heart load by controlling the rotation of continuous-flow LVAD, so it is synchronized with the cardiac beat. This novel driving system may be of great benefit to patients with end-stage heart failure, especially those with ischemic etiology.
Aortic insufficiency (AI) is a serious complication for patients on long-term support with left ventricular assist devices (LVAD). Postoperative aortic valve opening is an important predictor of AI. A system is presently available that can promote native aortic flow by reducing rotational speed (RS) for defined intervals. However, this system can cause a reduction in pump flow and lead to insufficient support. We therefore developed a novel "delayed copulse mode" to prevent AI by providing both minimal support for early systole and maximal support shortly after aortic valve opening by changing the RS in synchronization with heartbeat. To evaluate whether our drive mode could open the aortic valve while maintaining a high total flow (sum of pump flow and native aortic flow), we installed a centrifugal LVAD (EVAHEART(®); Sun Medical) in seven goats each with normal hearts and acute LV dysfunction created by micro-embolization of the coronary artery. We intermittently switched the drive mode from continuous (constant RS) with 100 % bypass to delayed copulse mode with 90 % bypass. Total flow did not significantly change between the two modes. The aortic valve opened when the delayed copulse mode was activated. The delayed copulse mode allowed the aortic valve to open while maintaining a high total flow. This novel drive mode may considerably benefit patients with severe heart failure on long-term LVAD support by preventing AI.
The system offers the possibility to control the left ventricular load by changing the rotational speed of a continuous-flow assist device in synchronization with the cardiac cycle. This system should provide the most favorable left ventricular loading conditions for recovery of the native heart.
The co-pulse mode of this novel RS modulation system may provide better pulsatility not only in the large vessels but also in the peripheral vasculature.
Our system enabled an increase in coronary arterial flow and a decrease in LV work load and afterload during VA-ECMO. The system offers the effects of VA-ECMO and an IABP in a single device.
Continuous-flow left ventricular assist devices (LVADs) have improved the prognosis of end-stage heart failure. However, continuous-flow LVADs diminish pulsatility, which possibly result in bleeding, aortic insufficiency, and other adverse effects. We previously developed a novel control system for a continuous-flow LVAD (EVAHEART; Sun Medical), and demonstrated that we could create sufficient pulsatility by increasing its rotational speed (RS) in the systolic phase (Pulsatile Mode) in the normal heart model. Here, we aimed to evaluate differences between systolic assist with advanced and delayed loads by shifting the timing of increased RS. We implanted EVAHEART in six goats (55.3 ± 4.3 kg) with normal hearts. We reduced their heart rates to <60 bpm using propranolol and controlled the heart rates at 80 and 120 bpm using ventricular pacing. We shifted the timing of increasing RS from -60 to +60 ms in the systolic phase. We found significant increases in all the following parameters when assessments of delayed timing (+60 ms) were compared with assessments of advanced timing (-60 ms): pulse pressure, mean dP/dt max of aortic pressure, and energy-equivalent pulse pressure. During continuous-flow LVAD support, pulsatility can be controlled using a rotary pump. In particular, pulsatility can be shifted by delaying increased RS.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.