The field of dentistry has seen various technological advances regarding caries detection, some lesions still prove to be difficult to detect. A reasonably new detection method, near-infrared (NIR), has shown good results in caries detection. This systematic review aims to compare NIR with conventional methods in terms of caries detection. Online databases (PubMed, Scopus, ScienceDirect, EBSCO, and ProQuest) were used for the literature search. The search was performed from January 2015 till December-2020. A total of 770 articles were selected, of that 17 articles qualified for the final analysis as per Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The articles were assessed according to a modified Critical Appraisal Skills Programme checklist, and then synthesis of the review started. The inclusion criteria were clinical trials done in vivo on teeth with active caries of vital or nonvital teeth. This review excluded nonpeer reviewed articles, case reports, case series, opinions, abstracts, non-English written articles, studies of subjects with arrested caries, or teeth with developmental defects of tooth structure and teeth having environmental defects of tooth structure, as well as in-vitro studies. The review compared near-infrared technology with radiography, visual inspection, and laser fluorescence in terms of caries detection, sensitivity, specificity, and accuracy. The sensitivity of NIR ranged from 99.1 to 29.1%. Studies showed that NIR exhibited higher sensitivity for occlusal enamel and dentin caries. The specificity of NIR ranged from 94.1 to 20.0%. In enamel and dentinal occlusal caries, NIR demonstrated lower specificity than that of radiograph. The specificity of NIR in early proximal caries was low. Accuracy was determined in 5 out of 17 studies where the values ranged from 97.1 to 29.1%. The accuracy of NIR was the highest for dentinal occlusal caries. NIR shows promising evidence as an adjunct in caries examination due to its high sensitivity and specificity; however, more studies are required to determine its full potential in different situations.
This work presents findings on utilizing the expansion stage of compressed air energy storage systems for air conditioning purposes. The proposed setup is an ancillary installation to an existing compressed air energy storage setup and is used to produce chilled water at temperatures as low as 5 °C. An experimental setup for the ancillary system has been built with appropriate telemetric devices to measure the temporal temperature variation, which consequently can be used to calculate the heat transfer and available cooling capacity. The system is compared to commercially available compression cooling air conditioners, and the potential of replacing them is promising, as one ton of conventional cooling can be replaced with a 500-L (0.5 m3) air tank at 20 bar operating for an hour. More tanks can be added to extend the operational viability of the system, which is also serving the original purpose of storing energy from grid excess or from solar photovoltaic panels. The thermal management has had the added benefit of increasing the roundtrip efficiency of the storage system from 31.4 to 35.2%, along with handling a portion of the cooling load.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.