Both treatment modalities were successful in moving the maxilla forward, proclining the maxillary incisors and retroclining the mandibular incisors. The more simple design of the tongue plate might therefore confer some advantages to this system in comparison with a facemask.
Mapping BSE and SE micrographs helped us to better understand the structure of materials on the surface of root canal dentin and MTA. Moreover, analysis of structure of materials on the surface of root canal dentine and MTA can be performed better by mapping of BSE and SE micrographs.
BackgroundTitanium-molybdenum alloy (TMA) and stainless steel (SS) wires are commonly used in orthodontics as arch-wires for tooth movement. However, plastic deformation phenomenon in these arch-wires seems to be a major concern among orthodontists. This study aimed to compare the mechanical properties of TMA and SS wires with different dimensions.Material and MethodsSeventy-two wire samples (36 TMA and 36 SS) of three different sizes (19×25, 17×25 and 16×22) were analyzed in vitro, with 12 samples in each group. Various mechanical properties of the wires, including spring-back, bending moment and stiffness were determined using a universal testing machine. Student’s t-test showed statistically significant differences in the mean values of all the groups. In addition, metallographic comparison of SS and TMA wires was conducted under an optical microscope.ResultsThe degree of stiffness of 16×22-sized SS and TMA springs was found to be 12±2 and 5±0.4, respectively, while the bending moment was estimated to be 1927±352 (gm-mm) and 932±16 (gm-mm), respectively; the spring-back index was determined to be 0.61±0.2 and 0.4±.09, respectively (p<0.001). There were no statistically significant differences in spring-back index in larger dimensions of the wires.ConclusionsSystematic analysis indicated that springs made of TMA were superior compared to those made of SS. Although both from economic and functionality viewpoints the use of TMA is suggested, further clinical investigations are recommended. Key words:Bending moment, optical microscope, spring-back, stainless steel, stiffness, titanium‒molybdenum alloy.
Aim. This study aims to evaluate the effect of acidic food simulant and (acetic acid 3%) on the shear bond strength (SBS) and adhesive remnant index (ARI) scores of one conventional and three different self-ligating brackets with different base designs. Materials and Methods. Freshly extracted first maxillary premolars (n = 160) were embedded in resin blocks. A conventional stainless steel bracket, Equilibrium 2, and three types of self-ligating brackets, Speed, In-Ovation R, and Damon 3MX, were bonded to teeth and exposed to distilled water (groups 1, 3, 5, and 7) or acetic acid 3% (groups 2, 4, 6, 8) for 12 weeks. SBS and ARI were calculated and statistical analysis was performed with the analysis of variance (SBS) or χ 2 test (ARI) to compare values between the different groups. Results. Equilibrium 2 and In-Ovation R showed a significantly lower SBS in the acidic environment than in distilled water. Significant differences in ARI scores were found for Equilibrium 2 after immersion in an acidic environment, shifting from 0 in distilled water to 2 in an acidic environment. Conclusions. Equilibrium 2 and In-Ovation R brackets showed a significant decrease in SBS after a 12-week immersion in acetic acid 3%, although all groups showed clinically acceptable SBS. Equilibrium 2 showed significant differences in ARI scores when exposed to acetic acid 3%.
The amount of daily intake of metals from orthodontic appliances over time is a matter of great concern. Nickel results in one of the most common metal-induced allergic contact dermatitis in humans; it produces more allergic reactions than all the other metals combined together. The purpose of this study was to evaluate the effects of thermocycling on the nickel release from orthodontic arch wires stored in artificial saliva with different pH values. Forty new wire pieces were selected. Each wire piece was placed in a special capillary Pyrex tube filled with artificial saliva, which was sealed and immersed in deionized water at 37 °C. The samples were divided into four groups of ten. Group I received no treatment; group II was subjected to thermocycling. The pH of storage in groups III and IV was reduced to 4.5, and group IV was subjected to thermocycling. Thermocycling was carried out between 5 and 55 °C for 500 cycles. The release of nickel ions was statistically analyzed by two-way ANOVA for the effects of two variables: pH and thermocycling. The interaction between pH and thermocycling was found to be statistically significant (F = 12.127, P = 0.001). Two-way ANOVA showed that different storage media or pH and thermocycling had a significant effect on the nickel release (F = 52.812, P < 0.001 and F = 197.035, P < 0.001, respectively). Thermocycling and pH can adversely affect the release of nickel from orthodontic wires, while thermocycling is clearly the dominant factor.
Spring characteristics of orthodontic wires e84
Social stress can alter the saliva in favor of metabolism of trace elements. This study aimed to assess the effect of social stress on salivary copper (Cu), zinc (Zn), manganese (Mn), and iron (Fe) contents in dental students before and after a comprehensive English test. Twelve students with an average age of 27 years were selected from three dental schools. The students were carries-free, and salivary samples were collected 1 week before the test day and right before the comprehensive English test. Unstimulated saliva was collected from the participants. The pH of the saliva samples was measured using a portable pH meter, and the salivary trace element contents were determined using an atomic absorption spectrophotometer. After checking data to be normally distributed, Student's paired t test was used for statistical analysis. Salivary pH significantly increased right before the English test. Salivary Cu concentration decreased in students after the test (P > 0.05). The level of Zn, Mn, and Fe increased, while only Mn change was statistically significant (P < 0.001). Under the limitations of this study, induction of social stress led to a significant increase in Mn concentration in the saliva. The salivary Cu, Zn, and Fe contents, however, did not exhibit significant changes. Changes in salivary inorganic trace element content, as a result of physiological stress, might influence health of teeth, enamel, and oral mucosal tissues.
One hundred elastomeric ligatures from one manufacturer were chosen for this study: 10 ligatures were tested at room temperature; the other 90 ligatures were divided into three equal groups and were stretched over stainless steel dowels. Group 1 samples were kept in artificial saliva. Group 2 samples were rinsed twice a day with 15 ml of Orthokin®, each time for 1 minute, and the Group 3 samples were rinsed twice a day with 15 ml of Oral B®, each time for 30 seconds, both samples being immersed in another artificial saliva prior to being put back in the test tubes. Each time, 10 of the samples were tested for their tensile strength at different intervals of 1, 7 and 28 days until they ruptured. One-way and two-way ANOVA and Tukey test were used for evaluation. Clinical Relevance: The aim of this study was to evaluate the in vitro effects of Orthokin®, Oral-B®, and artificial saliva on tensile bond strength of elastomeric ligatures.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.