Background-Long-term patency of conventional synthetic grafts is unsatisfactory below a 6-mm internal diameter.Poly(⑀-caprolactone) (PCL) is a promising biodegradable polymer with a longer degradation time. We aimed to evaluate in vivo healing and degradation characteristics of small-diameter vascular grafts made of PCL nanofibers compared with expanded polytetrafluoroethylene (ePTFE) grafts. Methods and Results-We prepared 2-mm-internal diameter grafts by electrospinning using PCL (M n ϭ80 000 g/mol).Either PCL (nϭ15) or ePTFE (nϭ15) grafts were implanted into 30 rats. Rats were followed up for 24 weeks. At the conclusion of the follow-up period, patency and structural integrity were evaluated by digital subtraction angiography. The abdominal aorta, including the graft, was harvested and investigated under light microscopy. Endothelial coverage, neointima formation, and transmural cellular ingrowth were measured by computed histomorphometry. All animals survived until the end of follow-up, and all grafts were patent in both groups. Digital subtraction angiography revealed no stenosis in the PCL group but stenotic lesions in 1 graft at 18 weeks (40%) and in another graft at 24 weeks (50%) in the ePTFE group. None of the grafts showed aneurysmal dilatation. Endothelial coverage was significantly better in the PCL group. Neointimal formation was comparable between the 2 groups. Macrophage and fibroblast ingrowth with extracellular matrix formation and neoangiogenesis were better in the PCL group. After 12 weeks, foci of chondroid metaplasia located in the neointima of PCL grafts were observed in all samples. Conclusions-Small-diameter PCL grafts represent a promising alternative for the future because of their better healing characteristics compared with ePTFE grafts. Faster endothelialization and extracellular matrix formation, accompanied by degradation of graft fibers, seem to be the major advantages. Further evaluation of degradation and graft healing characteristics may potentially lead to the clinical use of such grafts for revascularization procedures.
SummaryBackgroundStents are an alternative treatment to carotid endarterectomy for symptomatic carotid stenosis, but previous trials have not established equivalent safety and efficacy. We compared the safety of carotid artery stenting with that of carotid endarterectomy.MethodsThe International Carotid Stenting Study (ICSS) is a multicentre, international, randomised controlled trial with blinded adjudication of outcomes. Patients with recently symptomatic carotid artery stenosis were randomly assigned in a 1:1 ratio to receive carotid artery stenting or carotid endarterectomy. Randomisation was by telephone call or fax to a central computerised service and was stratified by centre with minimisation for sex, age, contralateral occlusion, and side of the randomised artery. Patients and investigators were not masked to treatment assignment. Patients were followed up by independent clinicians not directly involved in delivering the randomised treatment. The primary outcome measure of the trial is the 3-year rate of fatal or disabling stroke in any territory, which has not been analysed yet. The main outcome measure for the interim safety analysis was the 120-day rate of stroke, death, or procedural myocardial infarction. Analysis was by intention to treat (ITT). This study is registered, number ISRCTN25337470.FindingsThe trial enrolled 1713 patients (stenting group, n=855; endarterectomy group, n=858). Two patients in the stenting group and one in the endarterectomy group withdrew immediately after randomisation, and were not included in the ITT analysis. Between randomisation and 120 days, there were 34 (Kaplan-Meier estimate 4·0%) events of disabling stroke or death in the stenting group compared with 27 (3·2%) events in the endarterectomy group (hazard ratio [HR] 1·28, 95% CI 0·77–2·11). The incidence of stroke, death, or procedural myocardial infarction was 8·5% in the stenting group compared with 5·2% in the endarterectomy group (72 vs 44 events; HR 1·69, 1·16–2·45, p=0·006). Risks of any stroke (65 vs 35 events; HR 1·92, 1·27–2·89) and all-cause death (19 vs seven events; HR 2·76, 1·16–6·56) were higher in the stenting group than in the endarterectomy group. Three procedural myocardial infarctions were recorded in the stenting group, all of which were fatal, compared with four, all non-fatal, in the endarterectomy group. There was one event of cranial nerve palsy in the stenting group compared with 45 in the endarterectomy group. There were also fewer haematomas of any severity in the stenting group than in the endarterectomy group (31 vs 50 events; p=0·0197).InterpretationCompletion of long-term follow-up is needed to establish the efficacy of carotid artery stenting compared with endarterectomy. In the meantime, carotid endarterectomy should remain the treatment of choice for patients suitable for surgery.FundingMedical Research Council, the Stroke Association, Sanofi-Synthélabo, European Union.
Background-Inhaled nitric oxide (iNO) has been used to assess the vasodilator capacity of the pulmonary vascular bed in children with congenital heart disease and elevated pulmonary vascular resistance. Inhaled iloprost is a pulmonary vasodilator for the long-term treatment of pulmonary hypertension (PHT). Because these 2 vasodilators act through different pathways (release of cGMP or cAMP, respectively), we compared the pulmonary vasodilator capacity of each. Methods and Results-A total of 15 children with congenital heart disease and PHT who had elevated pulmonary vascular resistance (preoperative, nϭ10; immediately postoperative, nϭ5) were first given 20 ppm of iNO for 10 minutes; then, after baseline values were reached again, they were given aerosolized iloprost at 25 ng ⅐ kg Ϫ1 ⅐ min Ϫ1 for another 10 minutes. Finally, iNO and iloprost were given simultaneously for 10 minutes. With iNO, the pulmonary vascular resistance and systemic vascular resistance ratio decreased from 0.48Ϯ0.38 to 0.27Ϯ0.16 (PϽ0.001). Similarly, iloprost decreased the ratio from 0.49Ϯ0.38 to 0.26Ϯ0.11 (PϽ0.05). The combination had no additional effect on the resistance ratio. Plasma cGMP increased from 17.6Ϯ11.9 to 34.7Ϯ21.4 nmol/L during iNO (PϽ0.01), and plasma cAMP increased from 55.7Ϯ22.9 to 65.1Ϯ21.2 nmol/L during iloprost inhalation (PϽ0.05). Conclusions-In children with PHT and congenital heart disease, both iNO and aerosolized iloprost are equally effective in selectively lowering pulmonary vascular resistance through an increase in cGMP or cAMP, respectively. However, the combination of both vasodilators failed to prove more potent than either substance alone. Aerosolized iloprost might be an alternative to iNO for early testing of vascular reactivity and for the postoperative treatment of acute PHT.
Background-Cytotoxic oxidized LDL (oxLDL) has been shown to promote apoptosis in cultured vascular smooth muscle cells (VSMCs). We investigated the localization of oxLDL and its association with apoptosis and the expression of apoptosis-related proteins in early and advanced atherosclerotic lesions. Methods and Results-Atherosclerotic plaques (nϭ23) from patients undergoing aortic, carotid, or femoral arterial surgery were studied. In early lesions, oxLDL was located predominantly in the superficial intima and in the media just beneath the internal elastic lamina. Medial VSMCs staining positive for oxLDL showed expression of BAX, a proapoptotic protein of the BCL-2 family. Apoptosis, as detected by DNA in situ terminal deoxynucleotidyl transferase end-labeling (TUNEL), was not present in these early lesions. In advanced plaques, areas of the intima positive for oxLDL showed lower ␣-smooth muscle actin immunoreactivity (PϽ0.01) and higher BAX immunoreactivity (PϽ0.05). Furthermore, these areas showed an increased number of apoptotic VSMCs (PϽ0.01). Western blot analysis revealed that oxLDL increases BAX expression in cultured human coronary VSMCs. Conclusions-We conclude that in early atherosclerotic lesions, oxLDL-positive VSMCs express BAX, which increases the susceptibility of these cells to undergo apoptosis. This could be important in our understanding of the transition of early lesions into advanced atherosclerotic plaques, which are characterized by regions of cell death. In advanced plaques, oxLDL-positive areas of the intima show higher BAX immunoreactivity and TUNEL-positive VSMCs, and this may contribute to plaque instability and rupture.
about half of the total arterial compliance is located in the proximal thoracic aorta. Arterial reconstruction of the proximal aorta with a non-compliant graft results in a significant decrease in systemic arterial compliance, which in turn increases systolic and pulse pressure. The development of more compliant prosthesis, which matches the host artery compliance, is expected to reduce the hemodynamic changes induced after their implantation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.