Abstract-We propose three modeling methods using a mobile sensor network to generate high spatio-temporal resolution air pollution maps for urban environments. In our deployment in Lausanne (Switzerland), dedicated sensing nodes are anchored to the public buses and measure multiple air quality parameters including the Lung Deposited Surface Area (LDSA), a state of the art metric for quantifying human exposure to ultrafine particles. In this paper, our focus is on generating LDSA maps. In particular, since the sensor network coverage is spatially and temporally dynamic, we leverage models to estimate the values for the locations and times where the data are not available. We first discretize the area topologically based on the street segments in the city and we then propose the following three prediction models: i) a log-linear regression model based on nine meteorological (e.g., temperature and precipitations) and gaseous (e.g., NO2 and CO) explanatory variables measured at two static stations in the city, ii) a novel network-based log-linear regression model that takes into account the LDSA values of the most correlated streets and also the nine explanatory variables mentioned above, iii) a novel Probabilistic Graphical Model (PGM) in which each street segment is considered as one node of the graph, and inference on conditional joint probability distributions of the nodes results in estimating the values in the nodes of interest. More than 44 millions of geo-and time-stamped LDSA measurements (i.e., more than 14 months of real data) are used in this paper to evaluate the proposed modeling approaches in various time resolutions (hourly, daily, weekly and monthly). The results show that the three approaches bring significant improvements in R 2 , RMSE and FAC metrics compared to a baseline KNearest Neighbor method.
Abstract-Recent substantial progress in the domain of indoor positioning systems and a growing number of indoor locationbased applications are creating the need for systematic, efficient, and precise experimental methods able to assess the localization and perhaps also navigation performance of a given device. With hundreds of Khepera III robots in academic use today, this platform has an important potential for single-and multi-robot localization and navigation research. In this work, we develop a necessary set of models for mobile robot navigation with the Khepera III platform, and quantify the robot's localization performance based on extensive experimental studies. Finally, we validate our experimental approach to localization research by considering the evaluation of an ultra-wideband (UWB) positioning system. We successfully show how the robotic platform can provide precise performance analyses, ultimately proposing a powerful approach towards advancements in indoor positioning technology.
Abstract-Mobile Wireless Sensor Networks (WSNs) hold the potential to constitute a real game changer for our understanding of urban air pollution, through a significant augmentation of spatial resolution in measurement. However, temporal drift, crosssensitivity and effects caused by varying environmental conditions (e.g., temperature) in low-cost chemical sensors (typically used in mobile WSNs) pose a tough challenge for reliable calibration. Based on state-of-the-art rendezvous calibration methods, we propose a novel model-based method for automatically estimating the baseline and gain characteristics of low-cost chemical sensors taking temporal drift and temperature dependencies of the sensors into account. The performance of our algorithm is evaluated using data gathered by our long-term mobile sensor network deployment, developed within the Nano-Tera.ch OpenSense II project 1 in Lausanne, Switzerland. We show that, in a realistic context of sparse and irregular rendezvous events, our method consistently improves rendezvous calibration performance for single-hop online calibration.
Abstract-In recent years, a growing number of research groups have targeted the development and deployment of networks using low-cost chemical sensors for monitoring air quality. Due to economical reasoning, most of these systems make use of some sort of mobility to increase spatial coverage. The effect of mobility on measurement quality has, however, been largely neglected. The long response time of the chemical sensors typically used for this type of application, in conjunction with platform mobility, leads to significant signal distortion. While this problem can be addressed through signal deconvolution techniques, their effectiveness is limited by the typical poor Signal-to-Noise Ratio (SNR) of the measured signal. In this paper, we study the possibility of enhancing the measurement quality of chemical sensors through the use of active sampling (or sniffing). We propose different sniffer designs, employing both fans and pumps as actuators. Using a rigorous experimental framework, inside a wind tunnel, we study the ability of active samplers to increase measurement SNR, and thus indirectly to improve sensor dynamic response. We obtain a significant and consistent improvement in SNR for one of our pump-based sniffer designs. Finally, we validate the robustness of this signal enhancement in real-world conditions through an outdoor car-based experiment.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.