This paper examines an inductive power transfer (IPT) system with a rotary transformer as an alternative solution to slip ring systems for a contactless energy transfer to rotating equipment. A prototype system is set up, consisting of a rotating ball bearing shaft and an exemplary sensor circuit mounted on the shaft. Three possible transformer configurations are analyzed theoretically and experimentally regarding the self-inductance, the coupling factor and the losses in the litz wire. To utilize the intrinsic stray inductances of the rotary transformer, a series compensated resonant converter is implemented for the prototype system
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.