Fatty acid ethyl esters (FAEE) and ethyl glucuronide (EtG) were determined in 602 meconium samples in a maternal health evaluation study for detection of gestational alcohol consumption. A validated headspace solid phase microextraction method in combination with GC-MS was used for FAEE and the cumulative concentration of ethyl palmitate, ethyl linoleate, ethyl oleate, and ethyl stearate with a cut-off of 500 ng/g was applied for interpretation. A new and simple method was developed and validated for quantification of EtG from 10-20 mg meconium with D(5)-EtG as internal standard consisting of 30 min. extraction with methanol/water (1:1, v/v), evaporation of methanol, filtration of the aqueous solution through a cellulose filter and injection into LC-MS-MS. The limits of detection and quantification for EtG were 10 and 30 ng/g, the recovery 86.6 to 106.4% and the standard deviation of the concentrations ranged from 13% at 37 ng/g to 5% at 46,700 ng/g (N = 6). FAEE above the cut-off were found in 43 cases (7.1%) with cumulative concentrations between 507 and 22,580 ng/g and with one outlier of about 150,000 ng/g (EtG not detected). EtG was detected in 97 cases (16.3%) and concentrations between LOD and 10,200 ng/g with another outlier of 82,000 ng/g (FAEE 10,500 ng/g). Optimal agreement between the two markers was obtained with a cut-off for EtG of 274 ng/g and 547 cases with both FAEE- and EtG-negative, 33 cases with both FAEE- and EtG-positive, nine cases with FAEE-positive and EtG-negative, and seven cases with FAEE-negative and EtG-positive. Differences in physical, chemical, and biochemical properties and in the pharmacokinetic behavior are discussed as reasons for the deviating cases. In none of the 602 cases, serious alcohol consumption was reported by the mothers and no evidence for gestational ethanol exposure was observed in the medical investigation of the newborns. It is concluded that the combined use of FAEE and EtG in meconium as markers for fetal alcohol exposure essentially increases the accuracy of the interpretation and helps to avoid false positive and false-negative results.
Aim. Identification of women with moderate alcohol abuse during pregnancy is difficult. We correlated self-reported alcohol consumption during pregnancy and patient characteristics with objective alcohol indicators measured in fetal meconium. Methods. A total of 557 women singleton births and available psychological tests, obstetric data and meconium samples were included in statistical analysis. Alcohol metabolites (fatty acid ethyl esters (FAEEs) and ethyl glucuronide (EtG)), were determined from meconium and correlated with patient characteristics.
Results. We found that 21.2% of the 557 participants admitted low-to-moderate alcohol consumption during pregnancy. Of the parameters analyzed from meconium, only EtG showed an association with alcohol history (P < 0.01). This association was inverse in cases with EtG value above 120 ng/g. These values indicate women with most severe alcohol consumption, who obviously denied having consumed alcohol during pregnancy. No other associations between socioeconomic or psychological characteristics and the drinking status (via meconium alcohol metabolites) could be found. Conclusion. Women who drink higher doses of ethanol during pregnancy, according to metabolite measures in meconium, might be less likely to admit alcohol consumption. No profile of socioeconomic or psychological characteristics of those women positively tested via meconium could be established.
The heptafluorobutyric anhydride (HFBA), pentafluoropropionic anhydride (PFPA), and trifluoroacetic anhydride (TFAA) are compared as derivatizing reagents to use as the optimal method for the analysis of 10 amphetamines and cathinones in oral fluid. The target compounds were amphetamine (AMP), methamphetamine (MA), 4-methylamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxy-N-ethylamphetamine (MDEA), cathinone (CAT), methcathinone, mephedrone, and ephedrine. Amphetamine-D5, MA-D5, MDA-D5, MDMA-D5, and MDEA-D5 use as internal standards (IS). The analytes and IS were extracted from 0.5 mL of oral fluid by ethyl acetate in the presence of NaOH (0.1 N) as the base and then the dried extracts were derivatized with HFBA, PFPA, or TFAA at 70°C for 30 minutes. The limits of quantification based on signal-to-noise ratios ≥10 were ranged between 2.5 and 10 ng/mL. The calibration graphs were linear in the range of 5 or 10 to 1000 ng/mL for all analytes. Based on sensitivity, the PFPA is proved to be the best for derivatization of the target compounds prior to gas chromatography-mass spectrometry analysis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.