We report a method to profile the torsional spring properties of proteins as a function of the angle of rotation. The torque is applied by superparamagnetic particles and has been calibrated while taking account of the magnetization dynamics of the particles. We record and compare the torsional profiles of single Protein G-Immunoglobulin G (IgG) and IgG-IgG complexes, sandwiched between a substrate and a superparamagnetic particle, for torques in the range between 0.5 × 10(3) and 5 × 10(3) pN·nm. Both molecular systems show torsional stiffening for increasing rotation angle, but the elastic and inelastic torsion stiffnesses are remarkably different. We interpret the results in terms of the structural properties of the molecules. The torsion profiling technique opens new dimensions for research on biomolecular characterization and for research on bio-nanomechanical structure-function relationships.
Point-of-care B-type natriuretic peptide (BNP) testing with adequate analytical performance has the potential to improve patient flow and provide primary care givers with easy-to-use advanced diagnostic tools in the management of heart failure. We present the analytical evaluation of the Minicare BNP immunoassay under development on the Minicare I-20 platform for point-of-care testing. Analytical performance was evaluated using EDTA venous whole blood, EDTA plasma and capillary whole blood. Method comparison with a lab-testing system was performed using samples from 187 patients. Normal values were determined based on 160 healthy adults, aging from 19 to 70 years. Limit of blank (LoB), limit of detection (LoD) were determined to be 3.3 ng/L, 5.8 ng/L. Limit of quantitation (LoQ) in whole blood at 20% and 10% coefficient of variation (CV) was found < 9 ng/L and <30 ng/L respectively without significant differences between EDTA whole blood and EDTA plasma. Total CV was found to be from 6.7% to 9.7% for BNP concentrations between 92.6 and 3984 ng/L. The sample type comparison study demonstrated correlation coefficients between 0.97 and 0.99 with slopes between 1.03 and 1.09 between the different samples. Method comparison between Minicare BNP and Siemens ADVIA Centaur BNP demonstrated a correlation coefficient of 0.92 with a slope of 1.06. The 97.5% URL of a healthy population was calculated to be 72.6 ng/L. The Minicare BNP assay is a robust, easy-to-use and sensitive test for rapid determination of BNP concentrations that can be used in a near-patient setting.
BackgroundCapillary B-type natriuretic peptide (BNP) testing is attractive in outpatient and emergency settings. The aim of this study was to perform an evaluation of the clinical performances of capillary BNP testing as compared with venous whole blood and plasma point-of-care (POC) BNP as well as plasma N-terminal (NT) proBNP central laboratory testing.MethodsBNP was measured with a novel single epitope POC assay (Minicare® BV, Eindhoven, The Netherlands) and NT-proBNP with a central laboratory assay (Roche Diagnostics®, Vienna, Austria).ResultsBNP and NT-proBNP were measured in 269 patients of a Department of Cardiology (mean age 67.9 ± 13 years, 26.4% females). Capillary BNP very closely correlated with whole blood venous BNP (r = 0.99, p < 0.001). There was also a close correlation of plasma BNP and NT-proBNP concentrations (r = 0.79, p < 0.001). The diagnostic performances of capillary BNP, whole blood venous BNP, plasma BNP and plasma NT-proBNP for acute heart failure (areas under receiver operating characteristic curves [AUC ROC]: 0.73–0.77) or systolic left ventricular dysfunction in the whole study population (AUC ROC: 0.72–0.76) did not differ significantly. All were significant independent predictors of cardiovascular death during follow-up of the whole study population.ConclusionsOur study for the first time demonstrated a very close correlation of capillary and venous whole blood or plasma BNP concentrations using the same BNP assay in a large patient cohort. The diagnostic performances of different BNP specimens did not differ significantly, and no significant differences between BNP and NT-proBNP were found either.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.