We report two cases of proximal endograft collapse with an almost complete aortic occlusion after endovascular tube-graft treatment of thoracic aortic disease (thoracic aneurysm after a type B dissection, traumatic blunt aortic rupture) using the TAG Gore system. Oversizing of endografts is known to cause this complication. In our two cases, however, the oversizing was between 12% and 21.7%, which is less than the allowed oversizing of 25% that is recommended by the manufacturer. This endograft-related complication might be due to a poor alignment of the currently available endografts in highly angulated and tight aortic arches. In the first case, a combined endovascular and open emergent repair procedure achieved a reopening of the proximal endograft by proximal extension (TAG Gore). In the second case, proximal extension was not considered owing to a precise positioning of the endograft distal to the left carotid artery. A balloon-expanding Palmaz stent was therefore placed interventionally in the proximal part of the TAG graft to expand the endograft and to avoid another collapse of the device. This proximal endograft collapse has to be acknowledged as a potentially hazardous complication. We therefore recommend that the proximal part of thoracic endografts in the aortic arch should be closely monitored and we offer two possible endovascular solutions for resolving the problem of proximal endograft collapse.
We conclude that an increased ileal-mucosal-arterial delta PCO2 during porcine endotoxemia is related to impaired villus microcirculation. A putative contribution of disturbed cellular oxygen utilization resulting from "cytopathic hypoxia" may also assume importance.
In hyperdynamic porcine endotoxemia the plasma disappearance rate of ICG failed to accurately substitute for direct short-term measures of biliary ICG excretion. Hence normal values of plasma disappearance rate of ICG should be interpreted with caution in early, acute inflammatory conditions.
MR-guided balloon dilation of femoral and popliteal artery stenoses supported by real-time MR imaging and intra-arterial MR angiography is feasible with commercially available materials.
This study aims to evaluate the value of VEGF as a surrogate marker for peripheral vascular disease (PVD). Prior to treatment, serum VEGF levels were evaluated by enzyme-linked immunosorbent assay (ELISA) in 293 PVD patients. Risk factors and clinical parameters of PVD were documented. Twenty-six age-matched healthy volunteers served as controls. Serum VEGF values strongly correlated with Fontaine stages (p<0.006, stage IV vs. controls). High VEGF values prior to treatment were associated with poor outcome. Serum VEGF appears to indicate the severity of PVD and might serve as a surrogate indicator of disease severity.
Although NIC maintained hemodynamic stabilization during long-term endotoxemia, it was unable to improve LPS-induced deterioration of the hepato-splanchnic energy metabolism. More potent and selective PARS inhibitors are needed to elucidate the role of a PARS-dependent pathway in a clinically relevant models of sepsis.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.