A range of opportunistic pathogens have been associated with dental unit water systems (DUWS), particularly in the biofilms that can line the tubing. This study therefore aimed to assess the microbiology of DUWS and biofilms in general dental practices across seven European countries, including the United Kingdom (UK), Ireland (IRL), Greece (GR), Spain (ES), Germany (D), Denmark (DK) and the Netherlands (NL). Water supplied by 51% of 237 dental unit water lines exceeded current American Dental Association recommendations of < or = 200 colony-forming units (CFU) ml(-1). Microbiological loading of the source waters was between 0 (Denmark, the Netherlands and Spain) and 4.67 (IRL) log CFU ml(-1); water line samples from the DUWS ranged from 1.52 (ES) to 2.79 (GR) log CFU ml(-1); and biofilm counts ranged from 1.49 (GR) to 3.22 (DK) log CFU.cm(-2). Opportunistic pathogens such as legionellae (DK and ES), including Legionella pneumophila SG1 (DK and GR), and Mycobacterium spp. (DK, NL, GR, D and ES) were recovered occasionally. Presumptive oral streptococci (ES and NL), oral anaerobes (GR), Candida spp. (UK, NL and ES) and blood (GR and IRL) were detected at relatively low frequencies, but their presence indicated a failure of the 3-in-1 antiretraction valve, leading to back siphonage of oral fluids into the water and biofilm phase. These findings confirm that a substantial proportion of DUWS have high levels of microbial contamination, irrespective of country, type of equipment and source water. The study emphasizes the need for effective mechanisms to reduce the microbial burden within DUWS, and highlights the risk of occupational exposure and cross-infection in general dental practice.
Water delivered by dental unit water systems (DUWS) in general dental practices can harbor high numbers of bacteria, including opportunistic pathogens. Biofilms on tubing within DUWS provide a reservoir for microorganisms and should be controlled. This study compared disinfection products for their ability to meet the American Dental Association's guideline of <200 CFU · ml ؊1 for DUWS water. Alpron, BioBlue, Dentosept, Oxygenal, Sanosil, Sterilex Ultra, and Ster4Spray were tested in DUWS (n ؍ 134) in Denmark, Germany, Greece, Ireland, The Netherlands, Spain, and the United Kingdom. Weekly water samples were tested for total viable counts (TVCs) on yeast extract agar, and, where possible, the effects of products on established biofilm (TVCs) were measured. A 4-to 5-week baseline measurement period was followed by 6 to 8 weeks of disinfection (intermittent or continuous product application). DUWS water TVCs before disinfection ranged from 0 to 5.41 log CFU · ml ؊1 . Disinfectants achieved reductions in the median water TVC ranging from 0.69 (Ster4Spray) to 3.11 (Dentosept) log CFU · ml ؊1 , although occasional high values (up to 4.88 log CFU · ml ؊1 ) occurred with all products. Before treatment, 64% of all baseline samples exceeded American Dental Association guidelines, compared to only 17% following commencement of treatment; where tested, biofilm TVCs were reduced to below detectable levels. The antimicrobial efficacies of products varied (e.g., 91% of water samples from DUWS treated with Dentosept or Oxygenal met American Dental Association guidelines, compared to 60% of those treated with Ster4Spray). Overall, the continuously applied products performed better than those applied intermittently. The most effective products were Dentosept and Oxygenal, although Dentosept gave the most consistent and sustained antimicrobial effect over time.
The use of bacteriophages as potential indicators of faecal pollution has recently been studied. The correlation of the number of bacterial indicators and the presence of three groups of bacteriophages, namely somatic coliphages (SOMCPH), F-RNA-specific phages (FRNAPH) and phages of Bacteroides fragilis (BFRPH), in raw and treated wastewater and sludge is presented in this study. Raw and treated wastewater and sewage sludge samples from two wastewater treatment plants in Athens were collected on a monthly basis, over a 2-year period, and analysed for total coliforms, Escherichia coli, intestinal enterococci and the three groups of bacteriophages. A clear correlation between the number of bacterial indicators and the presence of bacteriophages was observed. SOMCPH may be used as additional indicators, because of their high densities and resistance to various treatment steps.
Natural mineral water from a UK spring was monitored at various stages after it was pumped from the ground, through to bottling and during shelf life before consumption. Samples were collected in commercial PVC bottles, in PVC bottles previously sterilized and hand-filled and in glass bottles. The bacterial flora was counted on plate count agar (PCA) and on PCA diluted 10 times (PCA/10). The predominant bacteria were identified to genus level. Growth rates and nutrient types of isolates were determined by the nutrient-tolerance test (NT). The plate counts at the pre-bottling stage were low. During storage larger numbers of bacteria grew in glass than PVC bottles; the largest number grew in PVC bottles filled by hand. Most of the pigmented bacteria isolated were oligocarbotolerant.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.