The meth od ol ogy, de vel oped for ac tive test ing of elec tronic de vices un der the ra di a tions, is pre sented. The test set-up in cludes a gamma-ray fa cil ity, the hard ware board/fix tures and the soft ware tools pur posely de signed and re al ized. The meth od ol ogy is so wide-rang ing to al low us the ver i fi ca tion of dif fer ent classes of elec tronic de vices, even if only ap pli ca tion ex am ples for static ran dom ac cess mem ory mod ules are re ported.Key words: test ing methodology, elec tronic de vice, to tal ion iz ing dose, sin gle event ef fect, gamma ray A. Parlato, et al.: The Meth od ol ogy for Ac tive Test ing of Elec tronic De vices .
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.