Radiation therapy is an established method of cancer treatment. New technologies in cancer radiotherapy need a more accurate computation of the dose delivered in the radiotherapy treatment plan. This study presents some results of a Geant4-based application for simulation of the absorbed dose distribution given by a medical linear accelerator (LINAC). The LINAC geometry is accurately described in the Monte Carlo code with use of the accelerator manufacturer's specifications. The capability of the software for evaluating the dose distribution has been verified by comparisons with measurements in a water phantom; the comparisons were performed for percentage depth dose (PDD) and profiles for various field sizes and depths, for a 6-MV electron beam. Experimental and calculated dose values were in good agreement both in PDD and in transverse sections of the water phantom.
Applying a reversible magnetic field during breast radiotherapy, not only reduces the dose to the lung and heart but also produces a sharp drop dose volume histogram for planning target volume, because of bending of the path of secondary charged particles toward the chest wall by the Lorentz force. The simulations have shown that use of the magnetic field at 1.5 T is not feasible for clinical applications due to the increase of ipsilateral chest wall skin dose in comparison to the conventional planning while 0.25 T is suitable for all patients due to dose reduction to the chest wall skin.
Orienting the B0 magnetic field parallel to the photon beam axis, LRBP geometry, tends to restrict the radial spread of secondary electrons which resulted in dose reduction to the lung. Dosimetry issues observed in both Linac-MR geometries, such as changes to the lateral dose distribution, significantly exhibited dose reduction in the contralateral organs on a representative breast plan. Further, the results show sharper edge dose volume histogram curves at 1.5 T for both geometries, especially in the LRBP configuration.
Rapid advances in biochemistry and genetics lead to expansion of the various medical instruments for detection and prevention tasks. On the other hand, food safety is an important concern which relates to the public health. One of the most reliable tools to detect bioparticles (i.e., DNA molecules and proteins) and determining the authenticity of food products is the optical ring resonators. By depositing a recipient polymeric layer of target particle on the periphery of an optical ring resonator, it is possible to identify the existence of molecules by calculating the shift in the spectral response of the ring resonators. The main purpose of this paper is to investigate the performance of two structures of optical ring resonators, (i) all-pass and (ii) add-drop resonators for sensing applications. We propose a new configuration for sensing applications by introducing a nanogap in the all-pass ring resonator. The performance of these resonators is studied from sensing point of view. Simulation results, using finite difference time domain paradigm, revealed that the existence of a nanogap in the ring configuration achieves higher amount of sensitivity; thus, this structure is more suitable for biosensing applications.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.