2017
DOI: 10.3390/s17051015
|View full text |Cite
|
Sign up to set email alerts
|

ZnO Film Bulk Acoustic Resonator for the Kinetics Study of Human Blood Coagulation

Abstract: Miniaturized and rapid blood coagulation assay technologies are critical in many clinical settings. In this paper, we present a ZnO film bulk acoustic resonator for the kinetic analysis of human blood coagulation. The resonator operated in thickness shear resonance mode at 1.4 GHz. When the resonator contacted the liquid environment, the viscous loading effect was considered as the additional resistance and inductance in the equivalent circuits, resulting in a linear relationship with a slope of approximately … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 21 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…The serum made a more obvious damping effect on the resonance, which accords with the fact that the serum has a higher viscoelastic constant than that of water. The Modified Butterworth-Van Dyke (MBVD) equivalent circuit model [38][39][40] was used to describe the electric characterization of the resonator. Table 1 summarizes the circuit parameters obtained by fitting the impedance curves measured in different mediums.…”
Section: Resonant Characteristics In Air and Liquidsmentioning
confidence: 99%
“…The serum made a more obvious damping effect on the resonance, which accords with the fact that the serum has a higher viscoelastic constant than that of water. The Modified Butterworth-Van Dyke (MBVD) equivalent circuit model [38][39][40] was used to describe the electric characterization of the resonator. Table 1 summarizes the circuit parameters obtained by fitting the impedance curves measured in different mediums.…”
Section: Resonant Characteristics In Air and Liquidsmentioning
confidence: 99%
“…As a result, the properties of sensitive coating determine the molecule recognitions, and directly affect the sensitivity, stability and reversibility of the sensor. Up to now, a variety of sensitive coatings, such as polymers [ 23 , 24 ], proteins [ 25 , 26 , 27 ], aptamers [ 28 , 29 , 30 , 31 ], enzymes [ 32 , 33 ], supramolecular monolayers [ 34 , 35 ], hydrophilic film [ 23 ] and CNTs [ 36 ] have been employed for FBAR sensors to achieve the selectivity for different analytes.…”
Section: Introductionmentioning
confidence: 99%
“…Acoustic biosensors, specifically the quartz crystal microbalance (QCM), the film bulk acoustic resonator (FBAR), and the surface acoustic wave (SAW), can provide valuable hemorheology information and feature advantages of fast and real-time electronic readout. Parylene-C passivated QCM exhibited enhanced signal stability and repeatability since using the typical QCM it was difficult to obtain steady curves owing to the frequency vibration and little frequency decrease .…”
mentioning
confidence: 99%
“…34,35 These POC devices have mainly focused on measurements of PT/INR and ACT (Table S1) and cannot perform kinetic measurements such as reaction time (R-TEG), clot formation time (K-TEG), maximum amplitude (MA-TEG), and clot formation rate (α-TEG). Acoustic biosensors, specifically the quartz crystal microbalance (QCM), 36−38 the film bulk acoustic resonator (FBAR), 39 and the surface acoustic wave (SAW), 40 can provide valuable hemorheology information and feature advantages of fast and real-time electronic readout. Parylene-C passivated QCM exhibited enhanced signal stability and repeatability since using the typical QCM it was difficult to obtain steady curves owing to the frequency vibration and little frequency decrease.…”
mentioning
confidence: 99%