2010
DOI: 10.1016/j.jscs.2009.12.009
|View full text |Cite
|
Sign up to set email alerts
|

Zinc(II) selective poly(vinyl chloride) membrane ISE using a macrocyclic compound 1,12,14-triaza-5,8-dioxo-3(4),9(10)-dibenzoylcyclopentadeca-1,12,14-triene as neutral carrier

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 14 publications
(3 citation statements)
references
References 27 publications
0
3
0
Order By: Relevance
“…These results contribute to the delicate modulation of metallacyclic receptors and anion recognition, in addition to anion sensor, anion transport, and molecular switching [102]. Chandra and Singh [103] have used 1,12,14-triaza-5,8dioxo-3(4),9(10)-dibenzoyl-1,12,14-triene as an excellent ion carrier to construct a highly selective electrode for determination of zinc ion ( Figure 5).…”
Section: Applicationsmentioning
confidence: 99%
“…These results contribute to the delicate modulation of metallacyclic receptors and anion recognition, in addition to anion sensor, anion transport, and molecular switching [102]. Chandra and Singh [103] have used 1,12,14-triaza-5,8dioxo-3(4),9(10)-dibenzoyl-1,12,14-triene as an excellent ion carrier to construct a highly selective electrode for determination of zinc ion ( Figure 5).…”
Section: Applicationsmentioning
confidence: 99%
“…27,28 Based on various parameters, the high stability and selectivity of its metal ion complex, its solubility and high ability to extract the metal ion into the paste phase, 2,11,20,29-tetra-tert-butyl-2,3naphthalocyanine was explored as an active material in carbon paste electrode for the fabrication of Zn 2+ selective sensor. Comparison between the proposed electrode and the reported Zn 2+ sensors based on macrocyclic ionophores [27][28][29][30][31][32][33][34][35] showed that the developed sensor has superiority over the reported electrodes in terms of low detection limit and fast response time (Table 1).…”
Section: Introductionmentioning
confidence: 99%
“…Numerous ionophores have been incorporated for the construction of Zn 2+ ISE such as cryptands, 15 sulipride drugs, 16 chalcogenides, 17 polypyrrole, 18 porphyrins, 19 bis(2-nitrophenyl)disulfide, 20 crown ethers, 21 thiazolidin-4-one, 22 macrocycles, 23,24 N,Nbis(acetylacetone)ethylenediamine, 25 tripodal chelating ligand 26 and many more. [27][28][29][30] However, these efforts have not been very beneficial as most of the reported sensors have suffered from narrow z E-mail: akscyfcy@iitr.ac.in; akscyfcy@gmail.com working concentration range, low pH range, high response time and substantial interferences from variety of cations.…”
mentioning
confidence: 99%