2018
DOI: 10.1016/j.quaint.2018.05.006
|View full text |Cite
|
Sign up to set email alerts
|

XRF scanning of discrete samples – A chemostratigraphic approach exemplified for loess-paleosol sequences from the Island of Susak, Croatia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(8 citation statements)
references
References 74 publications
0
8
0
Order By: Relevance
“…Same data sources as in Fig. 7 with additional data for Aquitaine loess (Sitzia et al, 2017), Carpathian loess (Profe et al, 2018;Schatz et al, 2015), North France loess (Smykatz-Kloss, 2003).…”
Section: Weatheringmentioning
confidence: 99%
See 2 more Smart Citations
“…Same data sources as in Fig. 7 with additional data for Aquitaine loess (Sitzia et al, 2017), Carpathian loess (Profe et al, 2018;Schatz et al, 2015), North France loess (Smykatz-Kloss, 2003).…”
Section: Weatheringmentioning
confidence: 99%
“…Correlation between CPA and Al2O3/SiO2 ratio in the loess samples from the study area (a) and Europe (b). Data sources: Carpathian loess (Bösken et al, 2017;Profe et al, 2018;Schatz et al, 2015;Újvári et al, 2014, 2008, North France/Belgium loess (this study, Chauvel et al, 2014;Gallet et al, 1998;Jamagne, 1973;Lautridou, 1985;Lautridou et al, 1984;Smykatz-Kloss, 2003), Rhine loess (this study, Kühn et al, 2013;Schatz et al, 2015;Taylor et al, 1983), Saxony/Poland loess (this study, Raczyk et al, 2015;Skurzyński et al, 2019Skurzyński et al, , 2017Waroszewski et al, 2018).…”
Section: Fig 12mentioning
confidence: 99%
See 1 more Smart Citation
“…Exposure times of 100 s per measuring point is a common setting for the Itrax XRF-CS when analyzing discrete samples 28 . With this setting, each resin sample needs around 30 minutes to finish the measurement (i.e.…”
Section: Resultsmentioning
confidence: 99%
“…Subsequent data processing for such a run involves deletion of every second spectrum which are biased by the acrylic glass rims of the sample cups (Ohlendorf, 2018), recalculation of a new sum spectrum containing sample spectra only, fit optimization of the new sum spectrum and batch processing of the sample spectra. This measurement protocol was applied to samples of several loess-paleosol sequences as these are usually discretely sampled and characterized by silt-sized particles which facilitates sample preparation (Profe et al, 2018a;Profe et al, 2018b;Profe et al, 2016;Zolitschka et al, 2014). All measurements yielded good data repeatability with a mean relative standard deviation of < 1.5 % for main elements except for Al (14.3 %) and Ba (14.9 %).…”
Section: Discrete Samples and Powdered Samplesmentioning
confidence: 99%