X-ray position-sensitive duo-lateral diamond detectors at SOLEIL

Abstract: The performance of a diamond X-ray beam position monitor is reported. This detector consists of an ionization solid-state chamber based on a thin single-crystal chemical-vapour-deposition diamond with position-sensitive resistive electrodes in a duo-lateral configuration. The detector's linearity, homogeneity and responsivity were studied on beamlines at Synchrotron SOLEIL with various beam sizes, intensities and energies. These measurements demonstrate the large and homogeneous (absorption variation of less t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…The intensity monitors must be small enough to fit into the experimental setup, fast enough to cope with a repetition rate of 4.5 MHz and highly transmissive. Diamond-based solidstate detectors are well known from synchrotron radiation applications, where they are used as beam-position monitors (BPMs) (Shu et al, 1998;Bergonzo et al, 1999;Desjardins et al, 2018). A diamond-based solid-state ionization chamber is located in the DES.…”
Section: Intensity Monitormentioning
confidence: 99%
“…The intensity monitors must be small enough to fit into the experimental setup, fast enough to cope with a repetition rate of 4.5 MHz and highly transmissive. Diamond-based solidstate detectors are well known from synchrotron radiation applications, where they are used as beam-position monitors (BPMs) (Shu et al, 1998;Bergonzo et al, 1999;Desjardins et al, 2018). A diamond-based solid-state ionization chamber is located in the DES.…”
Section: Intensity Monitormentioning
confidence: 99%
“…The position of the beam is reflected by an electronic grade single-crystal chemical-vapour-deposition (CVD) diamond X-ray BPM (Desjardins et al, 2013) located downstream of the sample slits and upstream of the fast shutter. The intensity of the X-rays and the flux deposited on the sample are measured on a duo-lateral position-sensitive detector (PSD; Desjardins et al, 2018). An additional placeholder for diagnostic tools is located downstream of the mirror box (Fig.…”
Section: Beam Diagnosticsmentioning
confidence: 99%
“…4(a)], despite slightly larger deviations observed in the region of higher X-ray energy. We note that the flux spectra were measured from the sum current of the quadrant-diamond XBPM Civi-2 (situated at the 40 m sample position), following a previous report (Desjardins et al, 2018). In the flux deduction, all absorptions from the filters and windows along the beam path were taken into account, including the attenuation due to the two diamond filters and the thin metal coatings of Rigi and Civi-2 XBPMs, and the Be windows.…”
Section: Beamline Opticsmentioning
confidence: 99%