2015
DOI: 10.1016/j.hedp.2015.08.001
|View full text |Cite
|
Sign up to set email alerts
|

X-ray opacity measurements in mid-Z dense plasmas with a new target design of indirect heating

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
28
1

Year Published

2017
2017
2020
2020

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 10 publications
(29 citation statements)
references
References 23 publications
(19 reference statements)
0
28
1
Order By: Relevance
“…The ratio between the two main structures (2p 1/2 → 3d 3/2 and 2p 3/2 → 3d 5/2 ) is highly sensitive to relativistic configuration interaction (i.e., Coulomb interaction between relativistic subconfigurations of a non-relativistic configuration). [30]. Comparison between experiment and our SCO-RCG calculation at T = 27 eV and ρ = 0.01 g/cm 3 .…”
Section: Interpretation Of Experimentsmentioning
confidence: 99%
See 2 more Smart Citations
“…The ratio between the two main structures (2p 1/2 → 3d 3/2 and 2p 3/2 → 3d 5/2 ) is highly sensitive to relativistic configuration interaction (i.e., Coulomb interaction between relativistic subconfigurations of a non-relativistic configuration). [30]. Comparison between experiment and our SCO-RCG calculation at T = 27 eV and ρ = 0.01 g/cm 3 .…”
Section: Interpretation Of Experimentsmentioning
confidence: 99%
“…X-ray transmission spectrum of copper was measured at "Laboratoire d'Utilisation des Lasers Intenses" (LULI) in France at the LULI2000 laser facility with an improved design of indirect heating [30]. The sample is a thin foil of mid-Z material inserted between two gold cavities heated by two 300 J, frequency-doubled (i.e., the wavelength of the laser is λ = 0.526 µm for a better X-ray conversion efficiency) nanosecond laser beams.…”
Section: Interpretation Of Experimentsmentioning
confidence: 99%
See 1 more Smart Citation
“…In ref. [24], this spectrum was also interpreted with the SCO-RCG code [22], and the differences between the two calculations are very small.…”
Section: Photoabsorption Experimentsmentioning
confidence: 99%
“…Finally, a mixed mode that allows one to deal with some configurations in detailed mode and other configurations in UTA mode has recently been implemented. The availability of these new features stimulates the effort in calculations aimed at obtaining accurate opacities in order to analyse data obtained in recent laser‐plasma experiments …”
Section: Introductionmentioning
confidence: 99%