2019
DOI: 10.1109/ted.2019.2903537
|View full text |Cite
|
Sign up to set email alerts
|

X-Ray Detector Based on All-Inorganic Lead-Free Cs2AgBiBr6 Perovskite Single Crystal

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
43
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 64 publications
(45 citation statements)
references
References 38 publications
2
43
0
Order By: Relevance
“…They are advantageous in strong X‐ray absorption, processable at low temperature, low‐cost fabrication, and superior semiconducting properties like low defect density, large mobility–lifetime product ( μτ ), long carrier diffusion length, etc. Noticeably, the recently reported X‐ray detectors based on 3D perovskites including MAPbI 3 [ 4,10–12 ] and CsFAMA [ 13 ] microcrystalline thin films or MAPbX 3 (X = Cl, Br, I and their mixture), [ 14–24 ] Cs x FA 1− x PbI 3 , [ 25 ] CsPbBr 3 , [ 26–29 ] and Cs 2 AgBiBr 6 [ 30–32 ] single crystals have realized high sensitivity with the highest up to 2.1 × 10 4 µC Gy air –1 cm –2 , significantly larger than the state‐of‐the‐art α‐Se X‐ray detectors. [ 33 ]…”
Section: Figurementioning
confidence: 99%
“…They are advantageous in strong X‐ray absorption, processable at low temperature, low‐cost fabrication, and superior semiconducting properties like low defect density, large mobility–lifetime product ( μτ ), long carrier diffusion length, etc. Noticeably, the recently reported X‐ray detectors based on 3D perovskites including MAPbI 3 [ 4,10–12 ] and CsFAMA [ 13 ] microcrystalline thin films or MAPbX 3 (X = Cl, Br, I and their mixture), [ 14–24 ] Cs x FA 1− x PbI 3 , [ 25 ] CsPbBr 3 , [ 26–29 ] and Cs 2 AgBiBr 6 [ 30–32 ] single crystals have realized high sensitivity with the highest up to 2.1 × 10 4 µC Gy air –1 cm –2 , significantly larger than the state‐of‐the‐art α‐Se X‐ray detectors. [ 33 ]…”
Section: Figurementioning
confidence: 99%
“…Meanwhile, their linear dynamic range of about 193 dB is compared favorably with those of the best‐performing LHP photodetectors based on CH 3 NH 3 PbI 3‐ x Cl x thin film (100 dB) or CH 3 NH 3 PbI 3 single crystals (222 dB), and even larger than those of the commercially available Si (120 dB) or InGaAs based (66 dB) photodetectors . In addition, the ultra‐high detection sensitivity of X‐ray detector based on Cs 2 AgBiBr 6 has up to 316 µCGyair −1 cm −2 , several times higher than that of the state‐of‐the‐art commercial α‐Se detectors (20 µCGyair −1 cm −2 ) …”
Section: Introductionmentioning
confidence: 95%
“…[ 23,24 ] Since then, X‐ray detection using many Pb‐based perovskites has been demonstrated. [ 25–40 ] To replace the toxic Pb, X‐ray detectors employing (C 8 H 17 NH 3 ) 2 SnBr 4 , [ 41 ] Cs 2 AgBiBr 6 , [ 42–45 ] Cs 3 Bi 2 I 9 , [ 46–48 ] (NH 4 ) 3 Bi 2 I 9 , [ 49 ] (BA) 2 CsAgBiBr 7 , [ 50 ] and Cs 2 TeI 6 [ 51 ] have been reported to demonstrate good sensitivity, and most of them significantly outperform the commercial α‐Se X‐ray detectors. However, some problems such as high‐temperature preparation, a large number of crystal defects, poor uniformity, low resistivity, and high leakage current, serious ion migration and instability are still serious enough to hamper their application in devices.…”
Section: Introductionmentioning
confidence: 99%