2013
DOI: 10.1016/j.cattod.2012.09.032
|View full text |Cite
|
Sign up to set email alerts
|

X-ray absorption spectroscopy and heterogeneous catalysis: Performances at the SOLEIL's SAMBA beamline

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
64
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 79 publications
(67 citation statements)
references
References 39 publications
1
64
0
Order By: Relevance
“…Fast in situ acquisitions were obtained using aQ uick-XAS monochromator equipped with ac hannel-cut Si(111)c rystal the oscillating movement of which was set to acquire one spectrum every 0.5 s. [47] The powdered sample was placed into ad edicated in situ cell, [48] positioned between two Ohken ionization chambers filled with nitrogen, for detection of the incident and transmitted X-rays. This cell enabled catalyst treatments to be performed under controlled conditions of temperature and gas flow.…”
Section: Characterization Of the Catalystsmentioning
confidence: 99%
“…Fast in situ acquisitions were obtained using aQ uick-XAS monochromator equipped with ac hannel-cut Si(111)c rystal the oscillating movement of which was set to acquire one spectrum every 0.5 s. [47] The powdered sample was placed into ad edicated in situ cell, [48] positioned between two Ohken ionization chambers filled with nitrogen, for detection of the incident and transmitted X-rays. This cell enabled catalyst treatments to be performed under controlled conditions of temperature and gas flow.…”
Section: Characterization Of the Catalystsmentioning
confidence: 99%
“…Because we used Pd mirrors to reject harmonics, the baseline was checked to ensure the absence of a residual Pd signal, owing to nonlinearity in the detectors. The experiments were conducted using the transmission and fluorescence cell fully described in [47]. 8 mg of catalyst, diluted 1:10 by weight with BN, and a total gas flow rate of 12 mL min À1 (0.5 % CH 4 , 2.0 % O 2 , 15.0 % H 2 O if needed, and N 2 balance) were used for Ce L III edge experiments.…”
Section: Operando Xafs Measurementsmentioning
confidence: 99%
“…Bulk Pd and Rh were also measured and used as references. The powder samples were placed inside the Lytle-type cell available on the beam line (Fontaine et al, 2013). The sample cell was connected to a gas distribution system that allows careful control of the gas mixture and the flow at atmospheric pressure.…”
Section: X-ray Absorption Spectroscopymentioning
confidence: 99%