2020
DOI: 10.1007/s11277-020-07432-w
|View full text |Cite
|
Sign up to set email alerts
|

Wireless Networks for Voltage Stability Analysis and Anti-islanding Protection of Smart Grid System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
10
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 16 publications
(18 citation statements)
references
References 10 publications
0
10
0
Order By: Relevance
“…On the other hand, hybrid IDMs based on signal processing technique [26,30] and communication-based remote IDMs [33,34,58] are accurate, efficient, fast, and reliable in detecting islands but they have high computational burden and cost concerns. Remote IDMs dominates the IDMs with its high speed of detection in the order of 20 ms with very small or almost zero NDZ.…”
Section: Summarized Results Of the Proposed Micro-synchrophasor Based Idmmentioning
confidence: 99%
See 1 more Smart Citation
“…On the other hand, hybrid IDMs based on signal processing technique [26,30] and communication-based remote IDMs [33,34,58] are accurate, efficient, fast, and reliable in detecting islands but they have high computational burden and cost concerns. Remote IDMs dominates the IDMs with its high speed of detection in the order of 20 ms with very small or almost zero NDZ.…”
Section: Summarized Results Of the Proposed Micro-synchrophasor Based Idmmentioning
confidence: 99%
“…Islanding detection factors such as detection time was within the prescribed limit of 2 s and the algorithm reported minimum false alarms. Katyara et al [34] proposed an anti-islanding technique utilizing wireless sensor networks. Phasor measurement units are the backbone for field data measurement and the same was transferred using wireless sensor networks.…”
Section: Literature Reviewmentioning
confidence: 99%
“…To the best of authors' knowledge, the existing protection schemes do not consider the phase angle jump information for coordination studies. The major contributions of this research are: (1) to investigate the effects of installing new DG on the voltage sag and protection coordination of utility network under different contingencies, (2) to improve an existing digital over-current relay with directional element using phase angle jump information, (3) to validate the performance and effectiveness of proposed scheme on simulated and real setups for its possible application in fields, (4) to examine the performance and robustness of proposed protection coordination scheme against other three state of art techniques.…”
Section: Related Workmentioning
confidence: 99%
“…Abnormalities include abrupt changes into the network characteristics due to different contingencies i.e., increased loading, frequent interruptions, sustained faults, etc. [1,2]. The traditional utility networks, being radial and passive are highly exposed to external disturbances but maintain their safety and security using conventional protection devices, as shown in Figure 1.…”
Section: Introductionmentioning
confidence: 99%
“…As for generation, the fuels including natural resources are the starting point for the generation cycle, whereas the transmission network links the power production to the distribution system and the distribution system is responsible for distributing power to the end-users. Apart from such basic components of the power system, the monitoring and controlling devices are equally important for maintaining the reliability, quality, and security of power being distributed and utilized [2] [3]. Further, the proper placement and coordination of protection devices is also a crucial aspect for avoiding unnecessary power outages and mitigating the contingencies at initial stages before they get worse by the time [4] [5].…”
Section: Introductionmentioning
confidence: 99%