2015
DOI: 10.1016/j.sna.2015.04.012
|View full text |Cite
|
Sign up to set email alerts
|

Wireguide driving actuator using resonant-type smooth impact drive mechanism

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(17 citation statements)
references
References 9 publications
0
17
0
Order By: Relevance
“…It is likely that this was done with direct contact between slider and measurement instrument.) Another option is to make the motor lift weights [83][84][85]. The force generation potential can also be estimated from the transient motor behaviour [86].…”
Section: Force Generationmentioning
confidence: 99%
See 2 more Smart Citations
“…It is likely that this was done with direct contact between slider and measurement instrument.) Another option is to make the motor lift weights [83][84][85]. The force generation potential can also be estimated from the transient motor behaviour [86].…”
Section: Force Generationmentioning
confidence: 99%
“…linear sawtooth without plateau [78,249] linear sawtooth with two plateaus [24,26,117,250] square, pulse [78,138,200,[251][252][253][254][255] two superposed sines [68,77,85,86,94,171] (b) Matsuda and Kaneko [45] present a motor operating with single cosine waves. This demonstrates that an inertia motor in single-step operation does not necessarily require an asymmetric driving signal, but this signal remains unique in literature.…”
Section: Voltage Signals For Low-frequency Operationmentioning
confidence: 99%
See 1 more Smart Citation
“…For conventional HIFU transducers that focus ultrasound from the outside, the focusing performance strongly relies on the working medium, however, our waveguide can directly orient the thin waveguide tip to the lesion for treatments and the output performances can be conveniently controlled by the waveguide design. Due to the direct contact between the solid waveguide and tissue, additional large mechanical vibration for direct contact tissue damage 2931 can be achieved besides the heating effects. So, by combining these effects, the tissue destruction efficiency can be improved.…”
Section: Introductionmentioning
confidence: 99%
“…Further, the special requirement on the input voltage (i.e. with one direction of the stroke fast and the opposite direction of the stroke slow) can be realized by the resonant principle (Yokozawa and Morita, 2015).…”
Section: Introductionmentioning
confidence: 99%