2018
DOI: 10.1016/j.measurement.2017.09.013
|View full text |Cite
|
Sign up to set email alerts
|

Wideband precision phase detection for magnetic induction spectroscopy

Abstract: Magnetic induction spectroscopy (MIS) has many applications providing a contactless impedance meausrement. However, MIS applications is currently limited due to the high precision of phase detection required over a wide band of frequencies. This paper focuses on phase detection aspect of the MIS and the advantages and disadvantages of various phase detection methods and phase detection subsystem architectures are discussed. The chosen phase detection method is investigated further and prototype hardware and so… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 9 publications
(12 reference statements)
0
5
0
Order By: Relevance
“…Magnetic Induction Spectroscopy (MIS) is one of the BIS techniques that uses electrical conductivity of materials as a function of frequency [ 34 ]. This technique is concerned with the investigation and measurement of spectra produced when magnetic fields interact with matter or emit electromagnetic radiation.…”
Section: Magnetic Induction Spectroscopy (Mis)mentioning
confidence: 99%
See 1 more Smart Citation
“…Magnetic Induction Spectroscopy (MIS) is one of the BIS techniques that uses electrical conductivity of materials as a function of frequency [ 34 ]. This technique is concerned with the investigation and measurement of spectra produced when magnetic fields interact with matter or emit electromagnetic radiation.…”
Section: Magnetic Induction Spectroscopy (Mis)mentioning
confidence: 99%
“…MIS also has great potential in biomedical engineering applications, especially due to its non-contact measurement capability [ 34 ]. MIS has been used on rabbits as a brain diagnostic device to differentiate between two types of strokes which are hemorrhagic and ischemic [ 51 ].…”
Section: Magnetic Induction Spectroscopy (Mis)mentioning
confidence: 99%
“…Our previous studies on MIS deal with hardware development [33], as well as characterizing ferromagnetic materials [34]. Various image reconstruction methods for soft field tomography techniques have been reviewed in [35].…”
Section: Introductionmentioning
confidence: 99%
“…Several MIT systems have been designed over the past three decades, most of which rely on circular helix coils sensors [2], [8], [9], [10], [11], [12], [13], [14]. The reason for this selection is, however, not well elaborated in the literature.…”
Section: Introductionmentioning
confidence: 99%