2017
DOI: 10.1002/bab.1528
|View full text |Cite
|
Sign up to set email alerts
|

Wide dynamic range of surface‐plasmon‐resonance‐based assay for hepatitis B surface antigen antibody optimal detection in comparison with ELISA

Abstract: Limit of detection (LOD), limit of quantification, and the dynamic range of detection of hepatitis B surface antigen antibody (anti-HBs) using a surface plasmon resonance (SPR) chip-based approach with Pichia pastoris-derived recombinant hepatitis B surface antigen (HBsAg) as recognition element were established through the scouting for optimal conditions for the improvement of immobilization efficiency and in the use of optimal regeneration buffer. Recombinant HBsAg was immobilized onto the sensor surface of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 26 publications
(15 citation statements)
references
References 43 publications
0
15
0
Order By: Relevance
“…Interestingly, despite this evidence, there are few clinical trials that have directly evaluated the effects of sustained exercise regimens on the brain health of inactive adults (Saucedo-Marquez et al, 2015 ; Church et al, 2016 ; Barha et al, 2017 ; Dinoff et al, 2017 ). The strategy immobilized antibodies onto sensor surfaces for quantification of protein using biosensors, which is more accurate and fast compared to traditional assays (Heinrich et al, 2010 ; Wöllner et al, 2010 ; Hu et al, 2013 ; Tam et al, 2017 ). The determination of levels of neurotrophins is usually performed by ELISA immunoassays; however, the use of biosensors opens a new possibility in obtaining results in real time, label free with a high sensitivity and specificity.…”
Section: Discussionmentioning
confidence: 99%
“…Interestingly, despite this evidence, there are few clinical trials that have directly evaluated the effects of sustained exercise regimens on the brain health of inactive adults (Saucedo-Marquez et al, 2015 ; Church et al, 2016 ; Barha et al, 2017 ; Dinoff et al, 2017 ). The strategy immobilized antibodies onto sensor surfaces for quantification of protein using biosensors, which is more accurate and fast compared to traditional assays (Heinrich et al, 2010 ; Wöllner et al, 2010 ; Hu et al, 2013 ; Tam et al, 2017 ). The determination of levels of neurotrophins is usually performed by ELISA immunoassays; however, the use of biosensors opens a new possibility in obtaining results in real time, label free with a high sensitivity and specificity.…”
Section: Discussionmentioning
confidence: 99%
“…Our results agreed with that reported in the literature stating that plasma and serum samples produce instrumental background noise [ 75 ]. However, using a reference channel in SPR-based assays helps in correcting non-specific adsorptions and compensating for refraction index differences [ 76 ]. An mAb-anti-TNF-α positive control was used for ensuring that Humira drug excipients did not cause antibody noise in interactions, unlike adalimumab.…”
Section: Discussionmentioning
confidence: 99%
“…In addition, Tam et al investigated the detection of hepatitis B surface antigen antibody ability using a surface plasmon resonance biosensor [90]. They obtained a linear performance in a range of 0.00098–0.25 mg/L, and a seven-fold higher limit of detection value, that a two-fold increase in the coefficient of variance of the replicated results, as compared with enzyme-linked immunosorbent assay.…”
Section: Latest Applications Of Biosensors On Virus Detectionmentioning
confidence: 99%