“…Other WAMS projects have been established in the past decade, including those in the U.S. Eastern Interconnection (EI) [17], Hydro Québec (Canada) [18], the SIMEFAS system in Mexico [19], China [20], [21], Brazil [22], Italy [23], the Nordic power systems [2], [24] and others. In the U.S. EI, WAMS has been successful in using PMUs for power system operations [12].…”
Section: A Wide-area Measurement Systemmentioning
confidence: 99%
See 2 more Smart Citations
“…Other WAMS projects have been established in the past decade, including those in the U.S. Eastern Interconnection (EI) [17], Hydro Québec (Canada) [18], the SIMEFAS system in Mexico [19], China [20], [21], Brazil [22], Italy [23], the Nordic power systems [2], [24] and others. In the U.S. EI, WAMS has been successful in using PMUs for power system operations [12].…”
Section: A Wide-area Measurement Systemmentioning
confidence: 99%
“…Present and past applications of WAMS and WACS at Hydro-Québec are discussed in [18] where recent studies have been focused on damping stability control. The WAMS implementation at Hydro-Québec shows that wide-area stabilizing PSS controllers using PMU information can improve the dynamic performance of the system [32].…”
Section: A Wide-area Measurement Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…Input signals can be categorized into two groups: local and "global" (also known as wide-area [Glavic and Van Cutsem (2009)]) signals. Although it has been shown in several studies that the former are less preferable to the latter [Kamwa et al (2006); Chow et al (2000); Kamwa et al (2005)], at present, global signals are seldom used in practice. In fact, two of the major challenges in the field are to adequately utilize global signals, and to select "appropriate" input signal types for power oscillation damping control; i.e., signals with high robustness and observability.…”
Section: Introductionmentioning
confidence: 99%
“…One of PMU-data based applications of wide-area monitoring systems (WAMS) that has received much attention recently is to exploit existing and potential remote signals from phasor measurement units (PMUs) [Kamwa et al (2006)] for inter-area mode control. Wide-area power oscillation dampers (WAPOD) may be used to damp oscillations in large interconnected networks [N.R.…”
Section: Introductionmentioning