Wide‐area measurement signal‐based stabiliser for large‐scale photovoltaic plants with high variability and uncertainty

Abstract: In this study, norm bounded linear quadratic Gaussian controller synthesis method is utilised to design a wide-area measurement signal (WAMS)-based power oscillation damping controller at photovoltaics (PV) plants. The uncertainties associated with the system are confined by the system matrices which are the affine functions of parameters belong to a convex polytopic region. A hybrid method based on Hankel singular value (HSV) and right-half-plane zeros (RHP-zeros) is utilised to assess and select the optimal … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 35 publications
(21 citation statements)
references
References 22 publications
0
21
0
Order By: Relevance
“…which is based on pole placement 8,9 ; and the other one is related to wide-area measurement system (WAMS). 10,11 In the small-signal stability analysis, due to linearization around the operating point, the nonlinear factors are not considered. However, the validity limitation of the model and parameter of the WAMS is not under consideration, and this can be regarded as an advantage.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…which is based on pole placement 8,9 ; and the other one is related to wide-area measurement system (WAMS). 10,11 In the small-signal stability analysis, due to linearization around the operating point, the nonlinear factors are not considered. However, the validity limitation of the model and parameter of the WAMS is not under consideration, and this can be regarded as an advantage.…”
Section: Discussionmentioning
confidence: 99%
“…In this scenario, a permanent three-phase fault occurs near bus 4 (in line [4][5][6][7][8][9][10][11][12][13][14] at the time of 2 seconds, and as the fault is not cleared after 0.1 seconds, the line 4-14 is gotten out of the circuit. The wind speed and solar irradiation patterns are considered similar to the first scenario.…”
Section: Third Scenario: Line Outage and Communication Failuresmentioning
confidence: 99%
“…In this section, an objective function based on eigenvalue is used to optimize parameters of damping controller . In this objective function, the real parts and the damping ratio of nondamping modes are formulated as follows: Min0.36emJ(),KGTG=w1truetrue∑i=1Ntruetrue∑ζiζ0ζ0ζi,k2+w2truetrue∑k=1Ntruetrue∑σiσ0σ0σi,k2 …”
Section: Objective Function Optimizationmentioning
confidence: 99%
“…The planned control loop is added to the control loops of RDC as given in Figure . The time‐delay operator es0.12emTd are often calculable by Pade approximation . A three‐order Padé approximation is applied in this paper.…”
Section: Control Scheme For Lwpgsmentioning
confidence: 99%