2018
DOI: 10.1007/s00216-018-0916-y
|View full text |Cite
|
Sign up to set email alerts
|

What is novel about certified reference materials?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(10 citation statements)
references
References 20 publications
(32 reference statements)
0
8
0
1
Order By: Relevance
“…Considering the variability of the serum results across the seven assays, we then used CRMs to investigate comparability based on certified values. As a primary reference material of lyophilized human insulin in buffer that is used to calibrate and validate measurement procedures, the employed CRMs are adept materials to compare the measurement results of different assays 26 . Although CRMs should ideally be commutable across different methods, for which the matrix is the major factor, presently there is no clear statement about commutability for immunoassay‐based analysis in currently available CRMs of human insulin.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Considering the variability of the serum results across the seven assays, we then used CRMs to investigate comparability based on certified values. As a primary reference material of lyophilized human insulin in buffer that is used to calibrate and validate measurement procedures, the employed CRMs are adept materials to compare the measurement results of different assays 26 . Although CRMs should ideally be commutable across different methods, for which the matrix is the major factor, presently there is no clear statement about commutability for immunoassay‐based analysis in currently available CRMs of human insulin.…”
Section: Resultsmentioning
confidence: 99%
“…As a primary reference material of lyophilized human insulin in buffer that is used to calibrate and validate measurement procedures, the employed CRMs are adept materials to compare the measurement results of different assays. 26 Although CRMs should ideally be commutable across different methods, for which the matrix is the major factor, presently there is no clear statement about commutability for immunoassay-based analysis in currently available CRMs of human insulin. Moreover, there is a significant gap in the concentration ranges between the typical clinical range and the studied CRMs, namely <150 pmol/L compared to >13.4 μmol/L, respectively, which means that repeated dilutions with increments of uncertainty and untraceable loss prevent any meaningful insight into comparability.…”
Section: Matrix Effectmentioning
confidence: 99%
“…In certain cases, a certified reference material linked to higher-order metrology with value and error assignments provided exists. Available compounds can be obtained from various organizations, such as the International Federation of Clinical Chemistry, National Institutes of Science and Technology, Joint Committee for Traceability in Laboratory Medicine, National Measurement Institute Australia, National Metrology Institute of Japan, and Korea Research Institute for Science and Standards [ 10 ]. These materials may also be included in commercial vendor catalogs.…”
Section: Analytical Materialsmentioning
confidence: 99%
“…According to the general requirements for the competence of reference material producers (ISO 17034:2016), a CRM is defined as a “reference material characterized by a metrologically valid procedure for one or more specified properties, accompanied by a reference material certificate that provides the value of the specified property, its associated uncertainty, and a statement of metrological traceability” [ 204 ]. Generally, major producers of RMs are NMIs [ 205 ]. However, RMs of SARS-CoV-2 are produced by not only NMIs, but also by commercial institutes and culture collections.…”
Section: Resources and Standardization For Sars-cov-2 Nucleic Acid Testingmentioning
confidence: 99%