1989
DOI: 10.2320/matertrans1989.30.137
|View full text |Cite
|
Sign up to set email alerts
|

Wettability of Solid Oxides by Liquid Pure Metals

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

3
15
1

Year Published

1998
1998
2008
2008

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(19 citation statements)
references
References 23 publications
3
15
1
Order By: Relevance
“…9, the "suggested" s-T relation (dashed line) and the mean value of reported measurements after Keene 9) are also drawn for comparison. The temperature dependence of the surface tension in the present work is very closer to that after Nogi et al 31) and the mean value of reported measurements after Keene than the "suggested" relation after Keene. Keene considered that the major error source in the surface tension measurements is the adsorption of surface active elements such as oxygen and sulfur on the surface of liquid metals, so that he decided the "suggested" relation based only upon the reported data having higher surface tensions.…”
Section: Surface Tension Of Liquid Agsupporting
confidence: 91%
See 1 more Smart Citation
“…9, the "suggested" s-T relation (dashed line) and the mean value of reported measurements after Keene 9) are also drawn for comparison. The temperature dependence of the surface tension in the present work is very closer to that after Nogi et al 31) and the mean value of reported measurements after Keene than the "suggested" relation after Keene. Keene considered that the major error source in the surface tension measurements is the adsorption of surface active elements such as oxygen and sulfur on the surface of liquid metals, so that he decided the "suggested" relation based only upon the reported data having higher surface tensions.…”
Section: Surface Tension Of Liquid Agsupporting
confidence: 91%
“…Solid circles and open circles are measurements of the present work using the constrained drop and the traditional sessile drop methods, respectively. Both data are within the scatter of reported values (solid lines 9,[27][28][29][30][31][32][33][34][35][36][37] in Fig. 8: Every data referred in this contribution (Figs.…”
Section: Surface Tension Of Liquid Agsupporting
confidence: 81%
“…Most studies of the wetting behavior of "pure" copper on alumina or sapphire indicate obtuse contact angles varying between 110° and 170° [20,22,55,[58][59][60][61][62][63][64], with more limited evidence suggesting that the contact angle decreases slightly with increasing temperature [59,62,63]. The copper-oxygen phase 8 Morozumi et al [27] report ≈50% bonded area after 1 h, 8.8 MPa, hv bonding at 1600°C.…”
Section: Brazing Using Copper-cuprous Oxide Eutectic and Joint Propermentioning
confidence: 99%
“…1, reported measurements are also drawn for comparison. 16,[18][19][20][21][22][23][24][25][26][27][28][29][30] Keene 30) asserted in his review that the surface tension of liquid metal measured using the sessile drop method could be lowly estimated due to the contamination from the substrates (mainly oxides), and the surface tension measured by the levitation method usually showed higher surface tension values than that by the sessile drop method because the sample in the levitation method might not be contaminated from the substrate. However, Egry et al 29) showed that the surface tension of liquid metal droplets measured by the levitation method had been highly estimated due to the electromagnetic pressure on the liquid metal.…”
Section: Surface Tension Of Pure Liquid Ag Cu and Snmentioning
confidence: 99%