2005
DOI: 10.1016/j.optcom.2005.03.037
|View full text |Cite
|
Sign up to set email alerts
|

Wavelength dispersion of Verdet constants in chalcogenide glasses for magneto-optical waveguide devices

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
22
1
1

Year Published

2005
2005
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 71 publications
(26 citation statements)
references
References 11 publications
2
22
1
1
Order By: Relevance
“…In all of the cases discussed here, the operating wavelength (vis-NIR) is on the low-frequency side of the electronic band gap, which is located at about 160 nm for the vitreous SiO 2 , [ 48 ] 350 nm for the terbium aluminosilicate, 400 nm for the tellurite glass and 580 nm for the chalcogenide glass. [ 49 ] As a result, the dispersion is normal (d n /d ω < 0) and the Verdet constant decreases at longer wavelengths (Figure 2 a).…”
Section: Case Study Imentioning
confidence: 98%
“…In all of the cases discussed here, the operating wavelength (vis-NIR) is on the low-frequency side of the electronic band gap, which is located at about 160 nm for the vitreous SiO 2 , [ 48 ] 350 nm for the terbium aluminosilicate, 400 nm for the tellurite glass and 580 nm for the chalcogenide glass. [ 49 ] As a result, the dispersion is normal (d n /d ω < 0) and the Verdet constant decreases at longer wavelengths (Figure 2 a).…”
Section: Case Study Imentioning
confidence: 98%
“…3(b). The calculation from the dispersion of the refractive index of As 2 S 3 films 12 and literature reports 7 indicate that line dispersion ␤ 2 of As 2 S 3 films at 1530 nm is about 4 ϫ 10 −3 to 6 ϫ 10 −3 ps 2 / cm and can be neglected. Therefore only the spectral broadening produced by SPM was considered in these simulations.…”
mentioning
confidence: 95%
“…For the light of a wavelength λ = 1550 nm the polarization rotation within the testing magnetic field induction range (0 ≤ B ≤ 30 mT) were immeasurably small. It is caused by a very strong dependence of the Verdet's constant value on wavelengths of light V = f (λ) [6,9]. (For λ = 1550 nm the Verdet constant V has above two order small value than for λ = 635 nm.)…”
Section: Results Of Measurementsmentioning
confidence: 99%
“…Measurements of the magnetic field may be realized by means of the Hall generator (so-called -hallotron) [3][4][5][6]. However, the application of hallotrons is often troublesome because electric motors generate disturbing magnetic field which affects operation of the sensor.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation