Volumetric Mapping of Barrett’s Esophagus and Dysplasia With en face Optical Coherence Tomography Tethered Capsule

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
33
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
6
2

Relationship

2
6

Authors

Journals

citations
Cited by 30 publications
(33 citation statements)
references
References 8 publications
0
33
0
Order By: Relevance
“…The cycloid scanner enables strip imaging at volumetric rates similar to reported capsule SECM frame rates, but with 3D depth-resolved imaging and nearly 9 × larger strip FOV [37]. The cycloid scanner can be extended to finer transverse resolution using a high NA design, as suggested in previously reported capsule designs using a focusing objective rotated by the micromotor [38,39]. …”
Section: Discussionmentioning
confidence: 92%
See 1 more Smart Citation
“…The cycloid scanner enables strip imaging at volumetric rates similar to reported capsule SECM frame rates, but with 3D depth-resolved imaging and nearly 9 × larger strip FOV [37]. The cycloid scanner can be extended to finer transverse resolution using a high NA design, as suggested in previously reported capsule designs using a focusing objective rotated by the micromotor [38,39]. …”
Section: Discussionmentioning
confidence: 92%
“…This work was followed by an OCT variant [36] and another variant with spectrally encoded confocal microscopy (SECM) [37] for side viewing of the esophageal circumference. Our group developed a micromotor tethered capsule using proximal manual pullback for volumetric and en face esophageal OCT imaging of up to 100 cm 2 field-of-view (FOV) in patients, but the manual pullback could not generate rapid volumetric rates [38]. We recently demonstrated what we believe is one of the first distal 2D scanning, circumferential side-viewing scanners incorporated into a tethered capsule, using a micromotor for the rotary (circumferential) scan and a pneumatic scanner for the longitudinal scan [39].…”
Section: Introductionmentioning
confidence: 99%
“…Investigators have recently combined VCSEL-based OCT systems with endoscopic probes that incorporate scanning micro-motors to obtain detailed three-dimensional views of BE architecture and blood flow (Fig. 15) [10,44,137]. This volumetric OCT opens new possibilities for obtaining additional features that may improve the diagnosis of BE.…”
Section: Gastrointestinal Tractmentioning
confidence: 99%
“…Proximal actuation via a long catheter with multiple bends produces nonuniform rotational and/or longitudinal distortion [4,5]. Recent catheters have used distal rotary scanning micromotors, reducing rotational distortion [68]. Our group developed new methods for side-viewing OCT that use distal actuation for 2D scanning [9].…”
mentioning
confidence: 99%
“…The en face plane at shallower depth showed circular/elliptical crypts and structural features reminiscent of crypt lumens. At deeper depths, OCT showed integrated effects of light propagation/backscattering; crypt walls produced high OCT signal, while lumens and stroma produced dark vertical features, resulting in contrast inversion [8]. Imaging of a benign hyperplastic polyp (Fig.…”
mentioning
confidence: 99%