“…Mesh electrodes have recently been shown to exhibit time-dependent features, in that at short times they act as microband electrodes followed by micro-ring behaviour, and at long times, they show voltammetric features that may be understood by comparison with a regularly-distributed (specifically cubically packed) partially blocked electrode. 72 The modified mesh, supported on one side with a transparent plastic backing, is then immersed into aqueous solutions and the potential scanned in the usual manner. It can be seen that this arrangement gives rise to quasi-steady-state oxidative currents, which generally increase with the number of individual mesh '' squares '' covered by the THPD liquid (Fig.…”