2019
DOI: 10.33961/jecst.2018.9.2.109
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric Determination of Droxidopa in the Presence of Tryptophan Using a Nanostructured Base Electrochemical Sensor

Abstract: A novel carbon paste electrode modified with Cu-TiO 2 nanocomposite, 2-(ferrocenylethynyl)fluoren-9-one (2FF) and ionic liquid (IL) (2FF/Cu-TiO 2 /IL/CPE) was fabricated and employed to study the electrocatalytic oxidation of droxidopa, using cyclic voltammetry (CV), chronoamperometry (CHA) and differential pulse voltammetry (DPV) as diagnostic techniques. It has been found that the oxidation of droxidopa at the surface of modified electrode occurs at a potential of about 295 mV less positive than that of an u… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
5
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
10

Relationship

5
5

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 33 publications
0
5
0
Order By: Relevance
“…Thirdly, nanomaterials can assist the electrode to preserve its characteristics for a long period of time [26]. So, a variety of nanomaterials have been synthesized and characterized for the electrochemical analysis [27][28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…Thirdly, nanomaterials can assist the electrode to preserve its characteristics for a long period of time [26]. So, a variety of nanomaterials have been synthesized and characterized for the electrochemical analysis [27][28][29][30][31][32].…”
Section: Introductionmentioning
confidence: 99%
“…However, a serious obstacle is that the oxidation peak potentials of the isomers are too close at a bare electrode which causes overlapping of voltammetric responses, making their discrimination very difficult [13][14][15][16][17]. A chemically modified electrode is a superior approach to solve the peak separation problem by applying a modifier [18][19][20][21][22][23][24]. Hence, a few modified electrodes have already been reported to determine HQ and CT such as GCE modified by carbon nanotubes (CNT), poly-amid sulfonic acid-CNTs, graphenechitosan composite, carbon nanotubes/poly (3-methylthiophene), penicillamine), Zn/Al layered double hydroxide film, or gold-graphene [25][26][27][28][29][30][31].…”
Section: Introductionmentioning
confidence: 99%
“…However, electro-chemical methods are growingly used for detecting analytes due to the benefits such as rapid responses, lower limits of detection, affordability, easy operations, and lack of pre-treatment. [14][15][16][17][18][19] Nevertheless, oxidation peak potential of the analyte has serious overlap in several bare solid electrodes. If improvement of selectivity is the goal; thus, separation of the signals from each other would be necessary.…”
mentioning
confidence: 99%