2005
DOI: 10.1016/j.electacta.2005.03.002
|View full text |Cite
|
Sign up to set email alerts
|

Voltammetric determination of ascorbic acid and dopamine in the same sample at the surface of a carbon paste electrode modified with polypyrrole/ferrocyanide films

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
54
0
3

Year Published

2008
2008
2017
2017

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 145 publications
(57 citation statements)
references
References 24 publications
0
54
0
3
Order By: Relevance
“…[1][2] The ability of the conductive/electroactive polymers such as polypyrrole, poly(1-naphthylamine), poly(ortho-toluidine) etc., for the fabrication of the modified electrodes prepared by an electropolymerization procedure have been demonstrated. [3][4][5][6][7] On the other hand, nitrite ion (NO 2 -) has been reported as a human health -hazard which extensively exists in the environment and usually uses in food preservation against food poisoning microorganism such as clostridium botulinum. 8 The surplus of nitrite would cause carcinogens because it is an essential precursor in the formation of Nnitrosamines.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2] The ability of the conductive/electroactive polymers such as polypyrrole, poly(1-naphthylamine), poly(ortho-toluidine) etc., for the fabrication of the modified electrodes prepared by an electropolymerization procedure have been demonstrated. [3][4][5][6][7] On the other hand, nitrite ion (NO 2 -) has been reported as a human health -hazard which extensively exists in the environment and usually uses in food preservation against food poisoning microorganism such as clostridium botulinum. 8 The surplus of nitrite would cause carcinogens because it is an essential precursor in the formation of Nnitrosamines.…”
Section: Introductionmentioning
confidence: 99%
“…Di antara jenis-jenis polimer konduktor, polipirol telah digunakan untuk memodifikasi elektroda karena polipirol memiliki konduktivitas listrik yang tinggi, mudah disintesis dalam pelarut air dan ketebalan film dapat dikendalikan dengan proses elektropolimerisasi (Kamalzadeh and Shahrokhian, 2014). Elektroda yang dimodifikasi dengan polipirol telah diaplikasikan untuk pengukuran asam askorbat (Raoof et al, 2005), atorvastatin (Kamalzadeh and Shahrokhian, 2014) dan epinefrin (Shahrokhian and Saberi, 2011).Dalam penelitian ini, screen printed carbon electrode (SPCE) yang dimodifikasi dengan polipirol secara elektropolimerisasi digunakan untuk analisis hidrokuinon (H 2 Q).…”
Section: Pendahuluanunclassified
“…This gives rise to overlapping oxidation peaks that are difficult to resolve [2,3]. In an attempt to resolve the oxidation peaks of DA and AA, various modified electrodes have been proposed and reported [4][5][6]. However, few of these have met with sufficient success to enable the development of a selective dopamine sensor.…”
Section: Introductionmentioning
confidence: 99%