2019 7th International Electrical Engineering Congress (iEECON) 2019
DOI: 10.1109/ieecon45304.2019.8938957
|View full text |Cite
|
Sign up to set email alerts
|

Voltage Observer-Based Control for Single-Phase Grid-Connected PV Inverter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 0 publications
0
3
0
Order By: Relevance
“…Inspired by the voltage observer (such as [33]), similarly, the average power observer of the DG# ik unit is expressed as, P̂ikbadbreak=Pik()tgoodbreak+0tjkNiaij()P̂jk()τP̂ik()τdτ$$\begin{equation}{\hat P_{ik}} = {P_{ik}}\left( t \right) + \int\limits_0^t {\sum_{jk \in {N_i}} {{a_{ij}}\left( {{{\hat P}_{jk}}\left( \tau \right) - {{\hat P}_{ik}}\left( \tau \right)} \right)d\tau } } \end{equation}$$where trueP̂jk${\hat P_{jk}}$ is the estimated average active power from its neighbour DGs.…”
Section: Proposed Distributed Decentralized Cooperative Control Schemementioning
confidence: 99%
See 1 more Smart Citation
“…Inspired by the voltage observer (such as [33]), similarly, the average power observer of the DG# ik unit is expressed as, P̂ikbadbreak=Pik()tgoodbreak+0tjkNiaij()P̂jk()τP̂ik()τdτ$$\begin{equation}{\hat P_{ik}} = {P_{ik}}\left( t \right) + \int\limits_0^t {\sum_{jk \in {N_i}} {{a_{ij}}\left( {{{\hat P}_{jk}}\left( \tau \right) - {{\hat P}_{ik}}\left( \tau \right)} \right)d\tau } } \end{equation}$$where trueP̂jk${\hat P_{jk}}$ is the estimated average active power from its neighbour DGs.…”
Section: Proposed Distributed Decentralized Cooperative Control Schemementioning
confidence: 99%
“…Inspired by the voltage observer (such as [33]), similarly, the average power observer of the DG#ik unit is expressed as,…”
Section: Average Active Power Observermentioning
confidence: 99%
“…A full-state feedback current controller with a reduced-order disturbance observer is proposed for single-phase grid-tied inverter systeme (Cheng et al, 2021), it can reduce the influence of uncertain interference factors and improve the robustness of the system. Reference (Hinsui and Sangtungtong, 2019) designed a voltage observer instead of a voltage sensor for the single-phase gridconnected inverter system, and it can achieve the same performance in comparison with the actual solar-array voltage.…”
Section: Introductionmentioning
confidence: 99%