2001
DOI: 10.1016/s0378-7796(01)00172-9
|View full text |Cite
|
Sign up to set email alerts
|

Voltage control integrated in distribution management system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
30
0
1

Year Published

2009
2009
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(31 citation statements)
references
References 5 publications
0
30
0
1
Order By: Relevance
“…Besides, improve voltage quality DMS Volt/Var and reduce losses as well [6][7][8], as well as Energy Audit implies tracing and reducing non-technical losses. The breakdown of electrical energy losses in networks distribution is presented in Fig.2.…”
Section: Benefits Of Dasmentioning
confidence: 99%
“…Besides, improve voltage quality DMS Volt/Var and reduce losses as well [6][7][8], as well as Energy Audit implies tracing and reducing non-technical losses. The breakdown of electrical energy losses in networks distribution is presented in Fig.2.…”
Section: Benefits Of Dasmentioning
confidence: 99%
“…Naponska regulacija je u zakonskoj regulativi prepoznata kao sistemska (pomoćna) usluga. Tržište električnom energijom u sadašnjim i budućim okvirima nameće nove zahteve svim učesnicima [6]- [7] i zahteva da proizvođačke i prenosne kompanije zajedno razvijaju nove metode za optimizaciju iskorišćenja reaktivnog kapaciteta (mogućnosti) generatora. Ovi zahtevi obično su definisani u preporukama regulatornih tela i obuhvataju: i) precizno određivanje limita u popdpobuđenoj zoni pogonske karte sinhronog generatora uzimajući u obzir kriterijume stabilnosti i termička ograničenja; ii) obezbeđivanje raspoloživosti punog reaktivnog opsega u svakoj radnoj tački u uslovima normalnih i havarijskih vrednosti napona u mreži; iii) generatori treba da rade sa faktorom snage od 0,9 induktivno do 0,95 kapacitivno i da održavaju napon na krajevima generatora u opsegu od 0,95 do 1,05 nominalne vrednosti.…”
Section: Uvodunclassified
“…Simultaneously with the voltage limitation criteria, it is also necessary to satisfy a certain optimisation criterion while solving this problem. The mentioned criterion can be the loss minimization, voltage sag minimization or damage minimization due to the voltage deviation from the referring (nominal) value [18,19]. The objective function, to be minimized, can be expressed through the following equation [19] ObjFun = min ∆V = min…”
Section: Equivalent LV Network Modelmentioning
confidence: 99%
“…Figure 10 shows the network voltage profiles at the maximum and minimum simultaneous powers of all the DGs, in cases when the optimal seasonal control plan is applied and when there is no optimal seasonal control plan (neutral positions of the tap changers of all the transformers). Treatment of the voltage limits: values of the upper and lower voltage limits in the MV and LV networks are specified according to the engineering standards (eg 105 and 95 %) [18]. Figure 10(a) clearly shows that by the correction of the voltage ratio at transformers 9, 10 and 15-16, in accordance with the optimal seasonal voltage control plan, the voltage values decrease at nodes 13, 17-20 and are brought down to a range within the standard limits (0.95 pu-1.05 pu).…”
Section: Case Study: 33-node Distribution Networkmentioning
confidence: 99%
See 1 more Smart Citation