1996
DOI: 10.1016/1352-2310(95)00116-6
|View full text |Cite
|
Sign up to set email alerts
|

Volatile organic compounds up to C20 emitted from motor vehicles; measurement methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
97
2

Year Published

1998
1998
2014
2014

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 146 publications
(102 citation statements)
references
References 19 publications
3
97
2
Order By: Relevance
“…It is shown that the concentration ratios for BTEX compounds measured at every monitoring station bear some resemblance to the ratios reported in the roadside study. The concentration ratios of the BTEX compounds--benzene/ethylbenzene (2.26-2.88), toluene/ ethylbenzene (3.62-5.63), o,m,p-xylene/ethylbenzene (4.32-5.97)--reported by other roadside studies and dynamometer studies (Zweidinger et al, 1988;Westerholm et al, 1996;Zielinska et al, 1996;Staehelin et al, 1998) are also comparable with the values in Fig. 3.…”
Section: Resultssupporting
confidence: 85%
“…It is shown that the concentration ratios for BTEX compounds measured at every monitoring station bear some resemblance to the ratios reported in the roadside study. The concentration ratios of the BTEX compounds--benzene/ethylbenzene (2.26-2.88), toluene/ ethylbenzene (3.62-5.63), o,m,p-xylene/ethylbenzene (4.32-5.97)--reported by other roadside studies and dynamometer studies (Zweidinger et al, 1988;Westerholm et al, 1996;Zielinska et al, 1996;Staehelin et al, 1998) are also comparable with the values in Fig. 3.…”
Section: Resultssupporting
confidence: 85%
“…2 No Nafion (Perma-Pure Products, Inc.) permeable membrane or other moisture-removal device is used prior to concentration because the use of such drying devices results in the loss of certain volatile compounds of interest. It can also introduce contaminants into the system and lower the total NMHC concentration by 10-20%.…”
Section: Analysis Methodsmentioning
confidence: 99%
“…2 About 10% of the prepared cartridges from each batch are analyzed to verify background carbonyl concentrations. The flow rates (~0.5 L/min) are measured at the beginning and at the end of each sampling period using a calibrated flow controller.…”
Section: Sampling Methodsmentioning
confidence: 99%
“…Sweet et al (1992), Scheff et al (1993), Kenski et al (1995), Zielinska et al (1996), Gee et al (1998), Mujica et al (1998, Singer et al (1999), Chan et al (2002), Doskey et al (2002), Na et al (2004Na et al ( , 2005.…”
Section: Rela Ción Entre Compuestosmentioning
confidence: 99%