2007
DOI: 10.1016/j.ajo.2006.10.051
|View full text |Cite
|
Sign up to set email alerts
|

Visual Field Defects After Macular Hole Surgery With Indocyanine Green–assisted Internal Limiting Membrane Peeling

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
38
1

Year Published

2007
2007
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 55 publications
(39 citation statements)
references
References 6 publications
0
38
1
Order By: Relevance
“…27,28,30 However, in our own experiments using AFM in fresh human tissue, an increase in stiffness was seen also for ICG without subsequent illumination maybe because the specimens were not kept in darkness as described for Wollensak's experimental setting. 27 It is widely accepted that the potential toxic effects of ICG 10,11,31,32 as described clinically are very likely related to photosensitizing properties of ICG as described above and the decomposition products of the ICG molecule after illumination. 7,8,33 Importantly, other additional relevant tissue-dye interactions seem to have a role as a causative effect for the increase in tissue stiffness, as increased rigidity was also seen for BBG in our experiments.…”
Section: Basement Membrane Rigidity C Haritoglou Et Almentioning
confidence: 99%
See 1 more Smart Citation
“…27,28,30 However, in our own experiments using AFM in fresh human tissue, an increase in stiffness was seen also for ICG without subsequent illumination maybe because the specimens were not kept in darkness as described for Wollensak's experimental setting. 27 It is widely accepted that the potential toxic effects of ICG 10,11,31,32 as described clinically are very likely related to photosensitizing properties of ICG as described above and the decomposition products of the ICG molecule after illumination. 7,8,33 Importantly, other additional relevant tissue-dye interactions seem to have a role as a causative effect for the increase in tissue stiffness, as increased rigidity was also seen for BBG in our experiments.…”
Section: Basement Membrane Rigidity C Haritoglou Et Almentioning
confidence: 99%
“…ICG became a subject of debate because of its potential toxicity, most likely related to its chemical instability and a photosensitizing effect that has been demonstrated experimentally, [6][7][8][9] which may lead to functional deficits in clinical practice. 10,11 A few years later, the triarylmethane dye brilliant blue became commercially available. On the basis of clinical and experimental studies published so far, brilliant blue seems to provide an improved safety profile compared with ICG.…”
Section: Introductionmentioning
confidence: 99%
“…TA may enhance the effect of ILM removal by not only helping absorption of edema but also directly protect the retinal neurons by down-regulating the expression of such proteins during or just after surgery. The visual field defects reported after ICG-assisted ILM peeling during macular hole surgery have been suggested to be caused by the retinotoxicity of ICG [16][17][18][19] . It is possible that the effect of ILM peeling is offset by the retinotoxicity of ICG.…”
Section: Discussionmentioning
confidence: 99%
“…Our finding that trypan blue inhibits proliferation and enhances apoptosis to a significantly lesser degree than ICG argues for its greater safety. Nevertheless, as with ICG, there is little consensus about its effects [10,11,12,13,14,15,16,17]. …”
Section: Discussionmentioning
confidence: 99%
“…However, complications associated with its use over the past decade have called its safety into question. ICG was found to be associated with the risk of retinal damage [6,7,8,9], atrophy of the retinal pigment epithelium (RPE) [10], damage to the photoreceptors and RPE cells [11,12], lower visual function outcome [13,14,15,16], loss of epiretinal cellular integrity [17], cellular toxicity [18,19,20], and other harmful effects. Recently, research groups also reported that ICG may persist in the ocular cavity up to 6 weeks after its application in surgery [21,22].…”
Section: Introductionmentioning
confidence: 99%