Abstract: This paper proposes a power predictive control (PPC) method for three-phase pulse width modulated (PWM) rectifiers without a proportional-integral (PI) controller. The proposed PPC method calculates the optimized voltage vector by analyzing the relationship between the virtual flux, active power, converter voltage, and filter parameters. Thus an overshoot does not occur and the fast and accurate power control becomes possible. The predictive algorithm computes the power error that would be produced by applying… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
42
0
1

Year Published

2016
2016
2022
2022

Publication Types

Select...
4
4
1

Relationship

1
8

Authors

Journals

citations
Cited by 98 publications
(43 citation statements)
references
References 28 publications
(32 reference statements)
0
42
0
1
Order By: Relevance
“…Meanwhile, the use of a PI controller may be result in the integrator wind‐up phenomenon. This will affect the dynamic‐state performance of the control variables . In this paper, the proposed method does not need the PI gain adjustment required by a conventional FCS‐MPC method.…”
Section: Dynamic Reference Design Of Afesmentioning
confidence: 99%
“…Meanwhile, the use of a PI controller may be result in the integrator wind‐up phenomenon. This will affect the dynamic‐state performance of the control variables . In this paper, the proposed method does not need the PI gain adjustment required by a conventional FCS‐MPC method.…”
Section: Dynamic Reference Design Of Afesmentioning
confidence: 99%
“…그 결과 낮은 스위칭 주파 수로 인해 출력 전류의 큰 리플 성분이 존재한다 [15], [16] . 높은 스위칭 주파수를 보장하여 출력의 리플 성분을 저감시키기 위해서 공간벡터변조기법(Space vector modulation, SVM)기반의 방법들이 연구되었다 [22], [23] . [22] [17], [18] .…”
Section: 서 론unclassified
“…Despite its simplicity, the AC-line currents derivative is required. Since this solution presents high noise sensitivity, other methods have been developed using virtual flux (VF) concept [9], [10], [16]- [21], Kalman filters [22], [23], disturbance observers [14], [24], hybrid parallel observers [25] and Luenberger observers [26]. Adaptive fullorder observers [12], [27] have been also proposed for grid voltage sensorless control.…”
Section: Introductionmentioning
confidence: 99%