Vertical electrostatic force in MEMS cantilever IR sensor

Abstract: A MEMS cantilever IR detector that repetitively lifts from the surface under the influence of a saw-tooth electrostatic force, where the contact duty cycle is a measure of the absorbed IR radiation, is analyzed. The design is comprised of three parallel conducting plates. Fixed buried and surface plates are held at opposite potential. A moveable cantilever is biased the same as the surface plate. Calculations based on energy methods with position-dependent capacity and electrostatic induction coefficients demo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
8
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
3
1
1

Relationship

2
3

Authors

Journals

citations
Cited by 6 publications
(10 citation statements)
references
References 5 publications
2
8
0
Order By: Relevance
“…Each conductor feels only the negative pressure due to the fields at its own surface. 15 Integration of this pressure over the surface gives the net force 18 and confirms the sign found here.) Fig.…”
supporting
confidence: 66%
See 2 more Smart Citations
“…Each conductor feels only the negative pressure due to the fields at its own surface. 15 Integration of this pressure over the surface gives the net force 18 and confirms the sign found here.) Fig.…”
supporting
confidence: 66%
“…An SEM image of one of these large cantilevers confirms this interpretation of the initial paddle deformation in null position. 18 When bias is applied, the fringes from the middle of the paddle are observed to shift toward the tip, increasing their spacing, while no change in the interference pattern is observed near the base of the paddle or arms. This indicates a lifting of the tip and flattening of the paddle with bias.…”
mentioning
confidence: 98%
See 1 more Smart Citation
“…The negative electrostatic pressure responsible for lifting the cantilever is proportional to the square of the electric field at the cantilever surface, and electric field should be proportional to the applied bias voltage V B . According to [3], the electrostatic lifting force F ES is inversely proportional to cantilever height z, and we find that FES can be approximated by the function…”
Section: Responsivitymentioning
confidence: 99%
“…An upward electrostatic force F ES appears when the device is biased as shown 2,3 . This is opposed by an elastic restoring force F E and a sticking force F C such as Casimir force 3,4 . The latter force will be ignored here.…”
Section: Introductionmentioning