2004
DOI: 10.1118/1.1637733
|View full text |Cite
|
Sign up to set email alerts
|

Verification of Ir-192 near source dosimetry using GAFCHROMIC®film

Abstract: Intravascular brachytherapy treatments of in-stent restenosis have been performed extensively using Ir-192 ribbon. Task Group 60 of the American Association of Physicists in Medicine (AAPM) recommends a dose reference point at 2 mm from the source center for these treatments. However, it is known that the source can be as close as 0.5 mm to the arterial wall if not centered in the lumen. Therefore, the source dosimetry needs to be characterized at these close distances to accurately determine the amount of dos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
27
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 33 publications
(27 citation statements)
references
References 15 publications
0
27
0
Order By: Relevance
“…[1][2][3][4][5][6][7] While many of the current polymer systems are utilized for two-or three-dimensional dose representation, high spatial resolution offers potential for successful implementation in point-based measurements. Radiochromic materials commercially available in GAFCHROMIC ® films ͑International Specialty Products, Wayne, NJ͒ have the desired high spatial resolution [8][9][10] and are able to provide sufficient signal from a subcubic millimeter volume.…”
Section: Introductionmentioning
confidence: 99%
“…[1][2][3][4][5][6][7] While many of the current polymer systems are utilized for two-or three-dimensional dose representation, high spatial resolution offers potential for successful implementation in point-based measurements. Radiochromic materials commercially available in GAFCHROMIC ® films ͑International Specialty Products, Wayne, NJ͒ have the desired high spatial resolution [8][9][10] and are able to provide sufficient signal from a subcubic millimeter volume.…”
Section: Introductionmentioning
confidence: 99%
“…( 24 ) There are several studies which fit a third order polynomial to the calibration data to convert NOD to dose. ( 21 , 25 , 26 ) Using this method, an increasing incline was obtained in our experiment in higher doses, which is in contrast with the saturation effect in the films.…”
Section: Methodsmentioning
confidence: 62%
“…Gafchromic film (MD-55, Nuclear Associates, USA) was used due to its excellent spatial resolution (0.2 mm), tissue equivalent 6.5 atomic number, and low sensitivity to room luminosity [19], [20], [21]. The MD-55 has a thickness of approximately 0.3 mm and dose ranges from 3 to 100 Gy.…”
Section: Methodsmentioning