2016
DOI: 10.1038/srep23606
|View full text |Cite
|
Sign up to set email alerts
|

Vectorial strain gauge method using single flexible orthogonal polydimethylsiloxane gratings

Abstract: A vectorial strain gauge method using a single sensing element is reported based on the double-sided polydimethylsiloxane (PDMS) Fraunhofer diffraction gratings structures. Using O2 plasma treatment steps, orthogonal wrinkled gratings were fabricated on both sides of a pre-strained PDMS film. Diffracted laser spots from this structure have been used to experimentally demonstrate, that any applied strain can be quantitatively characterized in both the x and y directions with an error of less than 0.6% and with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
18
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(19 citation statements)
references
References 26 publications
(30 reference statements)
1
18
0
Order By: Relevance
“…The proposed force sensor based on PDMS grating has a larger footprint than [11], and possesses better performance. Also using a PDMS grating, the relative error of strain measurement in [12] is less than 0.6%. In this paper, the average relative error is estimated as 0.59% (0.05N/8.5N, 8.5N is the average force in the test), which is comparable with this key factor in [12].…”
Section: Force Measurementmentioning
confidence: 96%
See 2 more Smart Citations
“…The proposed force sensor based on PDMS grating has a larger footprint than [11], and possesses better performance. Also using a PDMS grating, the relative error of strain measurement in [12] is less than 0.6%. In this paper, the average relative error is estimated as 0.59% (0.05N/8.5N, 8.5N is the average force in the test), which is comparable with this key factor in [12].…”
Section: Force Measurementmentioning
confidence: 96%
“…When the sensor is deformed under applied force, the transmission modes in the PDMS waveguide change, so that the force can be derived by measuring the light intensity loss of the waveguide. In addition, Guo et al [12] developed a strain measurement method based on PDMS grating. When the sample is stretched, the strain can be calculated by measuring the position shift of light spot due to the grating diffraction.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…[177][178][179] In contrast to the advanced photonic crystals, they used the simplest type of classical photonic crystals as the diffraction grating to diffract incident light. [177][178][179] In contrast to the advanced photonic crystals, they used the simplest type of classical photonic crystals as the diffraction grating to diffract incident light.…”
Section: Photonic Crystalsmentioning
confidence: 99%
“…It is worth mentioning that apart of the cell growth control, the wrinkled morphologies are of essential interest in many other research fields such as the metrology of polymeric thin films, adhesion control, design of diffraction gratings, and stretchable electronics …”
Section: Introductionmentioning
confidence: 99%