1993
DOI: 10.1016/0378-4274(93)90126-i
|View full text |Cite
|
Sign up to set email alerts
|

Variability of physiologically based pharmacokinetic (PBPK) model parameters and their effects on PBPK model predictions in a risk assessment for perchloroethylene (PCE)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
39
0

Year Published

1999
1999
2019
2019

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 67 publications
(43 citation statements)
references
References 13 publications
4
39
0
Order By: Relevance
“…In addition, DCA is produced in a roughly linear fashion from PERC (28,125) at levels consistent with production from TCA, the principal metabolite of PERC. An analysis of data on the dose-response and elimination kinetics of DCA formed from TCE led to the conclusion that another source of DCA was required in addition to TCA, but that the data were inconsistent with the second source being the initial oxidation step (126).…”
Section: Metabolism Oftcementioning
confidence: 92%
“…In addition, DCA is produced in a roughly linear fashion from PERC (28,125) at levels consistent with production from TCA, the principal metabolite of PERC. An analysis of data on the dose-response and elimination kinetics of DCA formed from TCE led to the conclusion that another source of DCA was required in addition to TCA, but that the data were inconsistent with the second source being the initial oxidation step (126).…”
Section: Metabolism Oftcementioning
confidence: 92%
“…The usual procedure for incorporating measures of variability and uncertainty into pharmacokinetic modeling is Monte Carlo (MC 1 ) simulation (Farrar et al, 1989;Bois et al, 1991;Hattis et al, 1990;Gearhart et al, 1993;Krewski et al, 1995). The core of this procedure is the specification of prior model parameter probability distribution functions (pdfs).…”
Section: Methodsmentioning
confidence: 99%
“…This practice is a source of the following concerns. First, handling single values in the presence of significant variability and uncertainty is inappropriate and may be misleading (Farrar et al, 1989;Bois et al, 1991;Hattis et al, 1990;Gearhart et al, 1993;Krewski et al, 1995). Usually derived from a small sample, the mean may not be representative or even meaningful.…”
mentioning
confidence: 99%
“…The solvents studied were perchloroethylene (PCE; Dallas et al 1994a, b;Gearhart et al 1993), styrene (Andersen and Ramsey 1983;Csanady et al 1994;Filser et al 1993;LoÈ f and Johanson 1993;Paterson and Mackay 1986;Perbellini et al 1988;Ramsey and Andersen 1984), and toluene (Droz et al 1989;Purcell et al 1990;Tardif et al 1993a, b), which have been widely used in industry and for which PB-PK models have been reported by several authors.…”
Section: Methodsmentioning
confidence: 99%
“…The tissue-gas partition coe cient of the fat compartment for perchloroethylene is 3020 in one model (Dallas et al 1994a), corresponding to 2-fold the values of 1450±1455 used in other models (Droz et al 1989;Gearhart et al 1993). For toluene, there is no big difference among the authors.…”
Section: Methodsmentioning
confidence: 99%