Variability in the amplitude of skeletal muscle responses to magnetic stimulation of the motor cortex in man

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
93
0
1

Year Published

1999
1999
2015
2015

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 148 publications
(105 citation statements)
references
References 36 publications
4
93
0
1
Order By: Relevance
“…Before placement of EMG electrodes, the skin was rubbed with a mildly abrasive material dipped in medical alcohol. The TMS site over the motor cortex was chosen as a hot spot (Traversa et al, 1997;Ellaway et al, 1998) [i.e., the coil location that produced MEPs in biarticular muscles (long heads of biceps and triceps) with the lowest TMS setting at rest]. The coil was oriented at a 45°angle to the midline with the handle pointing posteriorly.…”
Section: Methodsmentioning
confidence: 99%
“…Before placement of EMG electrodes, the skin was rubbed with a mildly abrasive material dipped in medical alcohol. The TMS site over the motor cortex was chosen as a hot spot (Traversa et al, 1997;Ellaway et al, 1998) [i.e., the coil location that produced MEPs in biarticular muscles (long heads of biceps and triceps) with the lowest TMS setting at rest]. The coil was oriented at a 45°angle to the midline with the handle pointing posteriorly.…”
Section: Methodsmentioning
confidence: 99%
“…We chose to hold the coil by hand to easily compensate for small movements of the participant's head during data collection. Indeed, it has been demonstrated that holding the coil by hand or by a holder induces a comparable MEP variability (Ellaway et al, 1998). Moreover, although image-guided TMS allows for higher resolution of the targeted sites with respect to holding the coil by hand, the two procedures brought about a comparable degree of MEP variability when high, suprathreshold stimulation intensities were used (Gugino et al, 2001).…”
Section: Methodsmentioning
confidence: 99%
“…During the stimulations, the subjects performed a slight symmetrical voluntary contraction of the target muscles to facilitate the response [19,35]. To compensate for the inherent variability of motor evoked potentials [12], 6 to 8 stimuli were given for each muscle and each coil position to collect a representative sample of responses.…”
Section: ■ Stimulationsmentioning