2010
DOI: 10.1016/j.ijrefrig.2009.09.006
|View full text |Cite
|
Sign up to set email alerts
|

Vapour condensation of R22 retrofit substitutes R417A, R422A and R422D on CuNi turbo C tubes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
12
0

Year Published

2011
2011
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 35 publications
(13 citation statements)
references
References 24 publications
1
12
0
Order By: Relevance
“…However, these values changed to be 32.3% and 15.3% at cooling water inlet temperature of 15 °C. Similar results have been observed by Fernández-Seara et al [16] for condensation on CuNi turbo C tubes. They reported that overall condensation HTC for R-417A is lowered by 65-76% than HTCs for R-22.…”
Section: Comparison Between R-22 and R-417asupporting
confidence: 91%
“…However, these values changed to be 32.3% and 15.3% at cooling water inlet temperature of 15 °C. Similar results have been observed by Fernández-Seara et al [16] for condensation on CuNi turbo C tubes. They reported that overall condensation HTC for R-417A is lowered by 65-76% than HTCs for R-22.…”
Section: Comparison Between R-22 and R-417asupporting
confidence: 91%
“…The continuous depletion of the ozone layer, which shields the earth's surface from the biologically damaging ultraviolet sunlight called UV-B radiation, has resulted in a series of international treaties demanding a gradual phase out of CFC and HCFC refrigerants. The CFCs have been phased out in developed countries since 1996, and 2010 in developing countries [6]. Initial alternative to CFCs included some hydro-chlorofluorocarbons (HCFCs), but they will also be phased out internationally by year 2020 and 2030 in developed and developing nations, respectively [7,8].…”
Section: Introductionmentioning
confidence: 99%
“…The most promising alternative refrigerants that emerged were R410A, R407C, R134a, and R290. This list has since been revised to include R419A, R404A and R507 [6,15].…”
Section: Introductionmentioning
confidence: 99%
“…Fourth-generation refrigerants are mainly hydrofluoroolefins (HFOs) with low GWP and low capacity [25][26][27]. Therefore, they are refrigerants that are mixed with HFCs [28][29][30], HFOs [31][32][33], and HCs [34][35][36]. Natural refrigerants are low-GWP, zero-ODP, high-capacity, low-pressure, and nontoxic [37][38][39].…”
Section: Introductionmentioning
confidence: 99%