2015
DOI: 10.1007/s00431-015-2602-9
|View full text |Cite
|
Sign up to set email alerts
|

Validity of non-invasive point-of-care hemoglobin estimation in healthy and sick children—a method comparison study

Abstract: Non-invasive Hb estimation by SpHb monitor is reasonably accurate in healthy neonates and children. It can be used in critically ill children and neonates, but in conjunction with lab confirmation of Hb values.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
10
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 28 publications
3
10
0
Order By: Relevance
“…TrueHb has been evaluated in adult population in India in a single study with encouraging results [4]. Massimo have poor accuracy in most of the studies, although the precision was greater at higher levels of Hb, similar to our study [6,13,[15][16][17]22].…”
Section: Discussionsupporting
confidence: 82%
See 2 more Smart Citations
“…TrueHb has been evaluated in adult population in India in a single study with encouraging results [4]. Massimo have poor accuracy in most of the studies, although the precision was greater at higher levels of Hb, similar to our study [6,13,[15][16][17]22].…”
Section: Discussionsupporting
confidence: 82%
“…Some devices that have the potential for use in field settings in India include invasive devices (require finger pricking for taking blood -HemoCue, TrueHb) and non-invasive devices (do not require pricking -Massimo's device and AJO spectroscopic device). HemoCue and Massimo's device have been validated and extensively evaluated in field settings [6,[10][11][12][13][14][15][16]. The findings are however not very consistent [12,[15][16][17].…”
Section: Introductionmentioning
confidence: 95%
See 1 more Smart Citation
“…The Pronto® device with DCI-mini™ sensors (Masimo Corporation, Irvine, CA) is designed for use with infants and children weighing 3 to 30 kg. The device has already been assessed in high-resource settings, primarily for continuous monitoring of pediatric patients in critical care settings [ 9 , 10 ], but evidence to support its use in Africa and for community-based screening is not yet available.…”
Section: Introductionmentioning
confidence: 99%
“…Since its introduction on the market more than half a decade ago, non-invasive SpHb has been the focus of numerous studies in pediatric, 1115 spine, 1618 trauma, 19, 20 obstetric, 2123 urological, 24 abdominal surgery, 25, 26 emergency, 2729 critically ill 3032 and other patient groups 3340 as well as a few review articles. 13 …”
Section: Discussionmentioning
confidence: 99%