2008
DOI: 10.1080/13102818.2008.10817562
|View full text |Cite
|
Sign up to set email alerts
|

Validation of Lab-on-Chip Capillary Electrophoresis Systems for Total RNA Quality and Quantity Control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2009
2009
2018
2018

Publication Types

Select...
7
1
1

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 5 publications
(5 reference statements)
0
9
0
Order By: Relevance
“…RnA concentrations that were determined in the degradation experiments showed that with lower RnA quality the calculated RnA concentration dropped down. these results show, as described earlier (8), that RNA quantification by the experion and the Bioanalyzer is less accurate than by using UV measurement.…”
Section: Determination Of Rna Quantitymentioning
confidence: 56%
See 1 more Smart Citation
“…RnA concentrations that were determined in the degradation experiments showed that with lower RnA quality the calculated RnA concentration dropped down. these results show, as described earlier (8), that RNA quantification by the experion and the Bioanalyzer is less accurate than by using UV measurement.…”
Section: Determination Of Rna Quantitymentioning
confidence: 56%
“…the integrity of RnA is a very critical aspect regarding downstream RnA based analysis like microarray technology and real time Rt-qPcR (1,3,5,6,8). low-quality RnA can compromise the results of such experiments.…”
Section: Introductionmentioning
confidence: 99%
“…An alternative platform (Experion) is reported to show superior reproducibility and quantity assessment. 9,39,40 The storage and release of quality samples are the sine qua non of a modern biobank, and biobank personnel assume this responsibility on behalf of patient donors, funders, and researchers, including those who ultimately develop new patient interventions. Biospecimen science focuses on improving the quality of a biobank's unique human sample resource, and will henceforth ensure that fewer research studies are discredited because of substandard samples.…”
Section: Discussionmentioning
confidence: 99%
“…This technology recently gained interest in the plant RNA community (reviewed in [33]), but is partly based on the ribosomal peak ratio (28S/18S). Since the relationship between this ratio and mRNA integrity appears to be unclear [40,48,50,51], RIN (RNA Integrity Number [36]) and RQI (RNA Quality Indicator [52]) values that take into account the complete electropherogram were introduced as a more solid measure for RNA integrity. However, these values were initially assigned by using electropherograms of various mammalian tissues to train the software in an adaptive learning approach.…”
Section: Discussionmentioning
confidence: 99%