Validation of iQM Active Process Control Technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
11
0

Year Published

2003
2003
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 4 publications
2
11
0
Order By: Relevance
“…Ancy et al report that more and more hospitals recognize the value of broadening the range of measurements obtained from automated blood gas analyzers [12] . In addition to these vital aspects, POCT is fundamentally useful, particularly for blood gases, in that it reduces pre-analytical errors, which alone account for some 62% of medical errors [13] , [14] , [15] . Rapid, reliable, easy-to-maintain cassette analyzers are currently available which are ideally suited to this kind of testing for the user (physicians, nurses and midwives).…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Ancy et al report that more and more hospitals recognize the value of broadening the range of measurements obtained from automated blood gas analyzers [12] . In addition to these vital aspects, POCT is fundamentally useful, particularly for blood gases, in that it reduces pre-analytical errors, which alone account for some 62% of medical errors [13] , [14] , [15] . Rapid, reliable, easy-to-maintain cassette analyzers are currently available which are ideally suited to this kind of testing for the user (physicians, nurses and midwives).…”
Section: Introductionmentioning
confidence: 99%
“…At the Clermont-Ferrand university teaching hospital, as part of a transfer of activity to the medical biochemistry laboratory, the blood gas analysis equipment was upgraded. For this purpose, Werfen equipment was selected, particularly for its analytical performance and ease of use for both clinical and laboratory staff; but most importantly, for the supplier's fully independent iQM system [6] , [7] , [13] , [17] , [18] . In all, 12 GEM PREMIER 4000 analyzers were deployed across 11 sites, throughout two hospitals, CHU Gabriel Montpied and CHU Estaing.…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, ARLs can be converted to units of time to characterize the average time until a rejection occurs, as illustrated in a published validation study of a new IQC technology. 28 …”
Section: Predict Iqc Performancementioning
confidence: 99%
“…Results of a validation study indicate that the error detection capabilities far exceed that expected of traditional IQC procedures. 28 …”
Section: What About Electronic Qc Versus Liquid Iqc?mentioning
confidence: 99%
“…2 The iQM system is conceptually consistent with EP23-A, Laboratory Quality Control Based on Risk Management, which was approved and published by the Clinical and Laboratory Standards Institute (CLSI) in October 2011. [3][4][5] This document provides guidance based on risk management for laboratories to develop quality control plans tailored to the particular combination of measuring system, laboratory setting, and clinical application of the test. Therefore, blood gas analysis is recognized as context-specific (e.g.…”
Section: Introductionmentioning
confidence: 99%