2012
DOI: 10.1016/j.foodchem.2011.10.073
|View full text |Cite
|
Sign up to set email alerts
|

Validation of a gas chromatography-electron capture detection of T-2 and HT-2 toxins in Chinese herbal medicines and related products after immunoaffinity column clean-up and pre-column derivatization

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2013
2013
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 48 publications
(23 citation statements)
references
References 15 publications
0
22
0
Order By: Relevance
“…Positive samples with DON contamination levels were found to range from 17.2 to 50.5 μg kg −1 , which was further confirmed using GC-MS. In 2012, Kong et al [ 188 ] further extended this method for the simultaneous determination of T-2 and HT-2 toxins. Following thorough validation, this was used for the analysis of TCMs and related products from various sources.…”
Section: Analytical Techniques Of Mycotoxinsmentioning
confidence: 99%
“…Positive samples with DON contamination levels were found to range from 17.2 to 50.5 μg kg −1 , which was further confirmed using GC-MS. In 2012, Kong et al [ 188 ] further extended this method for the simultaneous determination of T-2 and HT-2 toxins. Following thorough validation, this was used for the analysis of TCMs and related products from various sources.…”
Section: Analytical Techniques Of Mycotoxinsmentioning
confidence: 99%
“…Therefore, we used a further solid-phase extraction clean-up after the sample extraction in order to avoid these ion effects and not to overload the HPLC column. Generally, specific Mycosep or immunoaffinity SPE columns were used in other studies for additional cleaning of sample extracts [6,7,11,15,17]. In this study we tested four reversed-phase (RP) SPE cartridges, namely Strata-XL (6 mL, 200 mg, and 3 mL, 200 mg), Oasis HLB (6 mL, 200 mg) and Strata C-18-U (6 mL, 500 mg) with the above described clean-up procedure (Section 2.2).…”
Section: Optimization Of Sample Preparationmentioning
confidence: 99%
“…T-2 and HT-2 mycotoxins can be separated using both gas and liquid chromatographic (GC and LC) techniques [4][5][6][7]. GC determination involves an addition derivatization step prior to analysis [10][11][12], which extends the analysis time. For LC separation ultraviolet (UV) detection results in high analytical limits and non-selective separation due to the low UV absorbance of these mycotoxins, and consequently, it is not recommended for analysis of complex matrices [4].…”
Section: Introductionmentioning
confidence: 99%
“…; Kong et al . ). During the outbreak of severe acute respiratory syndrome (SARS) and hemagglutinin type 1 and neuraminidase type 1 (H1N1)‐influenza, banlangen was prescribed as a daily tea to prevent and treat infections in China (Liau et al .…”
Section: Introductionmentioning
confidence: 97%
“…Banlangen tea, made of the roots of Isatis tinctoria L., is a popular functional herbal tea in China (Wu et al 1997;Hamburger 2002;Liau et al 2007;Kong et al 2012). During the outbreak of severe acute respiratory syndrome (SARS) and hemagglutinin type 1 and neuraminidase type 1 (H1N1)-influenza, banlangen was prescribed as a daily tea to prevent and treat infections in China (Liau et al 2007).…”
Section: Introductionmentioning
confidence: 99%